Advertisement

— W128 (reuse) (N5242-20134 or N5242-20303) A53 port 2 bypass switch to front-panel Port 2
SOURCE OUT
— W127 (reuse) (N5242-20116 or N5242-20292) A37 port 2 source attenuator to A53 port 2
bypass switch
— W129 (reuse) (N5242-20117 or N5242-20293) A53 port 2 bypass switch to A54 port 2 bridge
— W130 (reuse) (N5242-20133) A53 port 2 bypass switch to A54 port 2 bridge
— W91 (N5222-20022) Port 4 RCVR D IN to A44 port 4 receiver attenuator
— W22 (N5222-20018) A31 port 4 coupler to front-panel Port 4 CPLR ARM
— W153 (Opt 029 only) (N5242-20310) Front panel port 2 CPLR THRU to A32 port 2 coupler
— W20 (N5222-20054) A31 port 4 coupler to front-panel Port 4 CPLR THRU
— W24 (N5222-20053) Port 2 CPLR THRU to A32 port 2 coupler
— W80
(N5222-20020)
— W152 (Opt 029 only) (N5242-20311) Front panel Port 4 CPLR THRU to A31 port 4 coupler
— W89 (N5222-20021) Port 3 RCVR C IN to A43 port 3 receiver attenuator
— W18 (N5222-20015) A30 port 3 coupler to front-panel Port 3 CPLR ARM
— W76 (N5222-20019) A35 port 3 source attenuator to front-panel Port 3 SOURCE OUT
— W14 (N5222-20030) A29 port 1 coupler to front-panel Port 1 CPLR ARM
— W132 (reuse) (N5242-20072 or N5242-20277) Front-panel Port 1 RCVR A IN to A42 port 1
receiver attenuator
— W124 (reuse) (N5242-20125 or N5242-20295) Front-panel Port 1 CPLR THRU to A52 port 1
bypass switch
— W123 (reuse) (N5242-20127 or N5242-20297) A52 port 1 bypass switch to front-panel Port 1
SOURCE OUT
— W144 (Opt 029 only) (N5242-20304) A52 port 1 noise bypass switch to A29 port 1 coupler
— W12 (N5222-20045) Port 1 CPLR THRU to A29 port coupler
— W151 (Opt 029 only) (N5242-20309) Front panel port 3 CPLR THRU to A30 port 3 coupler
* Loosen 3x screws on A33 Reference Mixer Switch board, then slide the board to the rear of the
instrument to connect the following two cables (N5242-20042 or N5222-20032 and
N5242-20043 or N5222-20033).
— W36 (reuse) (N5242-20042 or N5222-20032) Front-panel REF 1 RCVR R1 IN to A33
reference mixer switch
— W35 (reuse) (N5242-20043 or N5222-20033) A33 reference mixer switch to front-panel REF
1 SOURCE OUT
— W16 (N5222-20049) Port 3 CPLR THRU to A30 port 3 coupler
— W122 (reuse) (N5242-20128) A34 port 1 source attenuator to A52 port 1 bypass switch
Installation Note N5242-90123
A36 port 4 source attenuator to front-panel Port 4 SOURCE OUT
Installation Procedure for the Upgrade