• Flexible hoses can be used where the sited ambient temperature of the hose does not
• Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas hoses
• The hose should not be crushed or trapped or be in contact with sharp or abrasive edges.

To Connect the Gas Supply

1. Fit the 1/2" BSP (female) connector (supplied with the cooker in a separate kit) to the gas inlet at the rear of the
cooker interposing the gasket. Check the correct positioning of the connector as shown and always use two
suitable spanners (Fig 6b).
2. Connect the gas supply to the gas inlet at the rear of the cooker.
3. To avoid damage to the appliance gas rail inlet pipe tighten the fittings using two suitable spanners (Fig. 6b).
4. Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing
the solution over the connection. The presence of bubbles will indicate a leak. If there is a leak, tighten
the fitting and then recheck for leaks.
Fig 6a
Do not use a naked flame to test for leaks.
https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG...
exceed 70°C. These hoses must be manufactured in accordance with BS669 part 1 and be of
the correct construction for the type of gas being used.
can be identified by a either a red band or stripe on the rubber outer coating of the hose).
It should also not be subjected to corrosion by acidic cleansing agents.