Connecting the Feeder Cable
To connect the feeder cable to the cooker:
• Remove the four screws that hold shield "A" behind the cooker.
• Open the cable clamp "D" completely.
• Check the position of the U bolts on the terminal block "B" (Fig. 7a) according to the diagram in Fig. 7b and Fig.
7c.
• Insert the feeder cable into the cable clamp "D" and into the cable protector "C". The supply cable must be of a
suitable size for the current requirements of the appliance; see 'Feeder cable section' following.
• Connect the phase and earth cables to terminal "B" according to Figs. 7b and 7c.
• Pull the feeder cable and block it with the cable clamp "D".
• Re-mount shield "A".
The earth conductor must be left about 30 mm longer than the others.