Jandy AquaPure Ei Workbook page 13

Chlorine generator
Table of Contents

Advertisement

Connecting to Controller:
Set the controller type before making connections.
Changing the Controller
CON TROLLER
EOS/PEN TAI R
Flow
Salt
On/Of f
Out put
R
Some controllers require different interface protocols. The Ei has 3 different modes
depending on which controller it will be connected to. The default is set to Jandy L/M.
To change: turn the Ei OFF, then press and hold the OUTPUT button for ~6 seconds.
The controller setting will appear on the display. Continue holding the OUTPUT button
until the desired controller setting is displayed on the screen. Release the OUTPUT
button. The Ei is now ready to be wired to the controller.
IMPORTANT: The comm link should not be made until the correct controller has been
set on the Ei
If connecting to a AquaLink RS or PDA
follow wiring diagram carefully.
Fan
4 3 2 1
Notes:
CON TROLLER
JANDY K
Flow
Sa lt
On/Off
Outpu t
R
F an
To AquaLink RS
or PDA
CONTROLLER
JANDY L/M
Flow
Sal t
On/Off
Output
R
Default controller
is Jandy L/M.
Power Supply Wiring
2 . 5 am p f u se s
100- 265 V A C
13