INSTALLATION

This appliance must only be installed and used in rooms with permanent
!
ventilation to local standards.
Installation of the appliance and its connection to the electrical mains
must only be carried out by QUALIFIED PROFESSIONALS.
Before installation, it is important to check that the appliance is
DISCONNECTED from the electrical main service terminal. KRUGER™
declines all responsibility for any damages arising from installation in
breach of the regulations in force or from failure to comply with the
accident prevention regulations.
Installation Premises
For proper operation of a gas appliance, the air necessary for the combustion
of the gas must be able to flow into the room naturally.
The air must flow into the room directly through openings in the outside
walls. These openings must have an unobstructed cross-section not less
than 1.18CFM or 2m
appliance nameplate).
This opening must be constructed so that it will not be obstructed from inside
or outside, or constructed close to the floor. The opening is recommended to
be on the side opposite to that on which the flue gases are discharged.
If it is not feasible to provide these openings in the room where the appliance
is installed, the necessary air may be taken from an adjacent room, provided
that:
• This room is not a bedroom or a hazardous environment;
• This room has ventilation;
• The ventilation between the room where the appliance is installed and the
adjacent room have openings.
/h for each kw of power (see total power in kw on the
3
9