Technical Data; Process Medium And Scope Of Application - Samson 45-9 Mounting And Operating Instructions

Flow regulator
Table of Contents

Advertisement

Design and principle of operation

3.1 Technical data

3.1.1
Process medium and
scope of application
Flow control for district heating systems, ex-
tended piping systems and industrial appli-
cations
− Suitable for gases and liquids
− Max. temperature for liquids
− Max. temperature for gases
80 °C · 150 °C
 2)
− Flow range, max. 14.1 m³/h
− Differential pressure across the restriction
0.2 bar
∆p
 
restriction
− Valve size DN 15 to 50
− Pressure rating PN 16 and 25
The valve closes when the flow rate exceeds
the adjusted set point.
_
The materials used in the regulator are also
1)
resistant to high concentrations of glycol.
Nevertheless, glycol reacts when it comes into
contact with metals and causes acids to form.
We cannot prevent this reaction. Therefore,
prevent it by using suitable inhibitors.
Suitable for air and nitrogen with diaphragm
2)
Luft and seals made of FKM and PN 25
version
14
Noise emission
SAMSON is unable to make general state-
ments about noise emission as it depends on
the regulator version, plant facilities, process
medium and operating conditions.
!
Risk of hearing loss or deafness due to loud
noise.
Wear hearing protection when working near
150 °C
the regulator.
 1)
The Type 45-9 Regulator is not a safety
valve. If necessary, a suitable overpressure
protection must be installed on site in the
plant section.
Dimensions in mm · Weights in kg
The lengths and heights in the dimensional
drawings are shown in page 17 onwards.