Hengstler Signo 721.2 User Manual page 161

Preset counter
Table of Contents

Advertisement

Available languages

Available languages

10 Malfunctions
Overview of Errors
Error
Display remains dark
Counter does not count
Incorrect counting
Possible cause
Machine/plant not powered on
Defective voltage supply
Defective signal generator;
Counter does not receive any counting signals
Adjusted to incorrect mode of operation (F1)
Single-channel, directional input, differential counting,
phase discriminator
Incorrect adjustment of PNP/NPN logic and input level
(F3)
High-level does not exceed the upper amplitude
threshold; low-level does not fall below the lower ampli-
tude threshold
Continuous reset signal is applied
Continuous gate signal is applied
161
To be corrected by:
Operator
Qualified electrician
Skilled personnel
Skilled personnel
Skilled personnel
Qualified electrician
Qualified electrician
Qualified
electrician

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Signo 721.3Signo 721.4

Table of Contents