Specifications - Mastervolt MasterShunt 500 User Manual

Enhanced battery monitor with integrated main fuse
Hide thumbs Also See for MasterShunt 500:
Table of Contents

Advertisement

15 SPECIFICATIONS

15.1 TECHNICAL SPECIFICATIONS
Model
Article number
Function of instrument
Manufacturer
Voltage Measurement
Voltage accuracy
Current Measurement
Current accuracy
Maximum current
Ipsc (maximum prospective
short circuit fault current)
Amp Hours Configuration
Time remaining
State of charge accuracy:
Maximum number of configurable events
Readout:
Available languages:
Supply voltage
Powering capability
Power consumption
with MasterView Easy
connected / standby*
Dimensions
Weight
EN / MasterShunt / February 2011
MasterShunt
77020100
Battery measuring device for intelligent DC supply.
Mastervolt Amsterdam the Netherlands
0-60 V (0.1V resolution)
± 0.6 % ± 1 digit
0-10A: <0.2A resolution, 10-100A: <0.5A resolution, 100-1000A:
<5A resolution
± 0.8 % of reading ± 1 digit
300A continuously
400A for 10 min.
500A for 5 min.
600A for 2 min.
20000A circuit breaking current
30-10000 Ah (5 Ah resolution)
0-480 hours (1 min resolution)
± 1%
9
By means of external display or PC screen
English, Nederlands, Deutsch, Francais, Castellano, Italiano,
Norsk, Svenska, Suomi, Dansk, American
8-60 V DC
Up to 3 non powering MasterBus devices
18mA(@13.6V) / 10mA(@27.2V) Normal operation mode
See section 15.2
1,0 kg (2.2 lbs)
SPECIFICATIONS
25

Advertisement

Table of Contents
loading

Table of Contents