8 Specifications

8.1

Technical specifications

Product code
Battery types
Battery voltage
Voltage Measurement
Voltage accuracy
Current Measurement
Current accuracy
Maximum current (With busbar or T-
fuse 500A)
Parallel operation
Amp Hours Configuration
Time remaining
State of charge accuracy
Maximum number of configurable
events
Available languages
Supply voltage
Main fuse
Idle consumption
MasterBus powering
System information
Programmable alarms
Options
Remote panel
General
Dimensions, hxwxd
Weight
Protection degree
MasterShunt 500 – User and Installation manual
MasterShunt 500 (MasterBus)
77020110
0-10A: <0.2A resolution, 10-100A: <0.5A resolution, 100-600A: <5A resolution
Yes, for load currents which exceed 300A continuously
63
English, Nederlands, Deutsch, Francais,
Castellano, Italiano, Norsk, Svenska,
Suomi, Dansk.
bus bar included in MasterShunt, Class T fuse or ANL fuse to be ordered separately
23 mA (normal operation), <1 mA (power saving, MasterBus off)
Yes
e.g. time remaining, voltage, current, state of charge
warning low voltage, low state of charge, high voltage
EasyView 5
MasterShunt 500 (CZone)
Gel, AGM, flooded, Lithium Ion
12, 24 or 48 V DC
0-60 V (0.1V resolution)
± 0.6 % ± 1 digit
± 0.8 % of reading ± 1 digit
300A continuously
400A for 10 min.
500A for 5 min.
600A for 2 min.
30-10000 Ah (5 Ah resolution)
0-480 hours (1 min resolution)
± 1%
See related display settings
8-60 V DC
150 x 150 x 65 mm
5.9 x 5.9 x 2.6 inch
0.7 kg
1.5 lb
IP 21
21
77020115
Not applicable
Not applicable
Touch 10, Touch 5