6 FIRST START UP

At first start up with the MasterShunt installed,
MasterBus (via a MasterView display or the
MasterAdjust software) will guide you through the
Variable
Description
Basic set up
Language
Change the language at first start up. See chapter 5
for more instructions.
Battery capacity
Set the battery capacity to enable the MasterShunt
calculating the state of charge.
Battery type
Four different battery types can be selected. The
spiral battery belongs to the AGM batteries.
Nominal voltage
Nominal battery voltage, set at first set up.
Advanced mode
Reverse IN/OUT
Use this option for reversing input and output, when
you installed the load at the left of the MasterShunt.
Mode
Use this option for parallel (chapter 7) or single
device configuration. "I + U only: is an option to only
measure the current and voltage with the
MasterShunt configured as single device.
Complete
Complete
It is still possible now to check your settings. When
ready, press "Complete" to finish the first start up.
If you want to alter a first start up variable
afterwards, resetting the settings is necessary.
EN / MasterShunt / February 2011
following settings. See the concerning manual for
display navigation.
Factory sett.
English
Value from First
Setup
Value from First
setup
Value from First
setup
Off
Single device
FIRST START UP
Range
11 languages, see
section 14.1
30-10000Ah
Gel, AGM, Wet, Li-
ion battery
12V ,24V, 48V
Off, On
I + U only, Single
device,
Parallel
mode.