CONFIGURATION

12 EVENTS

Variable
Description
Events
Event 1 source
Select an event to serve as Event 1. Example:
Battery pre low can trigger a generator to start and
Battery full can trigger it to stop.
Event 1 target
Select a device to perform a task if Event 1 takes
place. Example: generator
Event 1 command
Select a command on the device you chose.
Event 1 data
Data is linked to the command, see figure 19.
Event 2 source
This screen appears after enabling Event 1. Select
an event to serve as Event 2.
Figure 19: Explanation of the function Event data
12.1 EVENTS WITH MASTERSHUNT AS EVENT SOURCE
Disabled
Voltage pre low, Voltage low, Voltage high, Battery pre low,
Battery low, Battery full,
Battery 20%, 40%, 60%, 80%, 100%
Charging
Timer 1, 2
12.2 EVENTS WITH MASTERSHUNT AS EVENT TARGET
There are no events with the MasterShunt acting as an event target.
20
Fact sett.
Disabled
Select...
Select...
Off
Disabled
Input is a pulse followed by a longer signal (1/0).
This could be a short period followed by a long
period of the Event source Battery low. The figure
shows a pulse switch to illustrate the input.
On changes the status to On at the first signal.
Off changes the status to Off at the first signal.
Copy lets the status follow the input.
Copy Invert lets the status follow the opposite of the
input.
Toggle changes the status at the first signal and
back at the second signal. It is often used in
combination with a pulse switch.
No events configured
Refer to chapter 9 Alarm menu
Battery SOC in % of capacity
The MasterShunt measures charging current.
Refer to chapter 11, Timer settings
Range
Refer to section 12.1
System dependent.
System dependent.
See figure 19.