Parallel Use - Mastervolt MasterShunt 500 User Manual

Enhanced battery monitor with integrated main fuse
Hide thumbs Also See for MasterShunt 500:
Table of Contents

Advertisement

PARALLEL USE

7 PARALLEL USE
For load currents which exceed 300A continuous
current, more than one MasterShunt can be installed
to monitor the same battery (bank). The
MasterShunts are then configured in parallel to the
1. Masterview Easy display
2. Bow thruster
3. Mastershunt in parallel 1, in Reversed setting
4. Mastershunt in parallel 2
For parallel setup of two MasterShunts, follow next
steps:
• Reset both Mastershunts to factory settings;
• During First start up select Advanced mode/
Parallel mode on one of the MasterShunts.
• Enter the serial number(s) of the other
MasterShunt(s), refer to figure 14. These
MasterShunt(s) will be the slave(s).
Figure 14: Parallel setting
14
battery, like shown. Figure 13 shows the parallel
configuration of two MasterShunts (3) and (4) and
other products.
5. DC Distribution 500
6. Digital DC 10x10A
7. Battery
8, 9. MasterBus Terminator
The measurements of all parallelled MasterShunts
are combined and shown as one MasterShunt.
The currents however are shown separately, see
figure 16. This means, renaming the MasterShunts
can be convenient (see figure 15).
Figure 15: Renaming MasterShunts
Figure 13: System example 2
MSH MasterShunt
Bow
Inverter
thruster
- 8.0 A
0.0 A
Figure 16: MasterView display
February 2011 / MasterShunt / EN

Advertisement

Table of Contents
loading

Table of Contents