Replacing The 2.5" Sas Backplane - Fujitsu PRIMERGY TX150 S6 Service Supplement Manual

Hide thumbs Also See for PRIMERGY TX150 S6:
Table of Contents

Advertisement

Replacing the 2.5" SAS backplane

Ê Remove the four screws (two at each side) that fasten the 3.5" SAS/SATA
backplane holder to the hard disk cage.
Ê Take the 3.5" SAS/SATA backplane together with the holder out of the server.
Be careful with the isolation foil positioned on the rear side of the 3.5"
SAS/SATA backplane.
Ê Remove the isolation foil and lift the 3.5" SAS/SATA backplane from the
holder.
Ê Position the isolation foil on the new 3.5" SAS/SATA backplane.
Ê Insert the new 3.5" SAS/SATA backplane in the holder.
Ê Fasten the 3.5" SAS/SATA backplane holder using the four screws on the
hard disk cage.
Ê Attach the connectors of the SAS cable, the power cable and the I
to the 3.5" SAS/SATA backplane (see the
Ê Attach the green cable clamp to the connector of the I
cable in the cable clamp.
Ê Reinstall all hot-plug hard disk drives.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.6
Replacing the 2.5" SAS backplane
Two 2.5" SAS backplanes are mounted on the hard disk cage. It is not
necessary to remove the hard disk cage before replacing the SAS/SATA
backplanes.
Ê Open the server as described in the
Ê Remove all the hot-plug hard disk drives (for a description see the Operating
Manual).
V
CAUTION!
Check if all hard disk drives are uniquely identified so that you can
reinsert them into their original bays.
24
figure 6 on page
section "Preparation" on page
Service Supplement
Replacement routines
2
C cable
23).
2
C cable and place the
17.
TX150 S6

Advertisement