Rack Model; Opening The Server; Removing The Rack Front Cover - Fujitsu PRIMERGY TX150 S6 Service Supplement Manual

Hide thumbs Also See for PRIMERGY TX150 S6:
Table of Contents

Advertisement

Preparation
Ê Disengage the three tabs on the left side one after the other and rotate the
front cover outward about 2 cm.
Ê Press the two touch points of the lower hooks inward.
Ê Push the drive cover downward.
Ê Press strongly on the upper right cant of the front cover to release the upper
hook and pull out the front cover sideward.
4.1.2

Rack model

I
You will find a detailed description of "Opening the server" and
"Removing the rack front cover" in the Options Guide TX150 S6.
Ê Terminate all applications and shut down the server correctly.
Ê If your operating system has not switched off the server, press the on/off
button for at least four seconds ("Power override" function).
Ê Pull all power connectors out of the power outlets.
4.1.2.1

Opening the server

Ê Loosen the four knurled screws and pull the server as far as possible out of
the rack.
Depending on how accessible the server is in the rack cabinet, it can make
sense to remove it from the cabinet. You will find a detailed description in the
Options Guide or the Operating Manual.
Ê Loosen the two knurled screws at the server's rear side.
Ê Push back the top cover approxiate 2 cm.
Ê Remove the top cover.
4.1.2.2

Removing the rack front cover

Remove the rack front cover when making the following replacements:
– Replacing the operating panel
– Replacing the DVD/DVD-RW drive
– Replacing the intrusion switches
Ê Remove two screws on either side.
18
Service Supplement
Replacement routines
TX150 S6

Advertisement

Table of Contents
loading

Table of Contents