PARTS LIST

ITEM NO.
PART NO.
1
56073C
Bubbler Assy
2
40319C
Fitting - Orifice
3
50171C
O-Ring
4
50314C
Orifice - Flow Straightener
5
56011C
Housing Assembly
6
55997C
Pedestal
7
75580C
Bubbler Locknut
8
98118C
Bubbler Assembly VR
9
100322740560
Gasket - Black .68 x 1.03 VR
10
15009C
Nipple - Bubbler VR
11
28474C
Basin - Swirlflow
12
28473C
Lower Shell
13
45767C
Fountain Body
14
28343C
Cover Plate
15
45781C
Sleeve
16
45847C
Pin - Push Button
17
45848C
Push Button
18
50986C
Holder - Regulator
19
61313C
Regulator
20
15005C
Retaining Nut
21
56163C
Gasket - Drain
22
45769C
Assy - Drain/Tailpipe
23
45768C
Drain - Plug 1-1/2"
24
56092C
Poly Tubing (Cut To Length)
25
28392C
Back Panel RH ADA
28393C
Back Panel LH ADA
26
AP99
AP-99 Panel (Optional)
27
111008343890
Screw - #10-24 x .62 HHMS
28
70432C
Screw - #8-32 x .38 THSM
29
38417001
Screw - #8-18 x .37 HHSM
30
75560C
Screw - 5/16-18 x 1.00 HHMS
31
75632C
Setscrew - #10-32 x .31
32
70817C
Fttng - Elbow 1/4 x 1/4
33
55996C
Strainer
34
75671C
Spring - Push Button
35
28844C
Back Panel Assy RH ADA
28845C
Back Panel Assy LH ADA
NS
27090C
Hanger Bracket
Figure 16 – Back Panel Assembly
Installing Back Panel: When installing back panel
assy. (Item 35) with MPW (Mounting Plate), attach
channel braces as shown above. Remove the
protective backing from the tape installed on the
braces. Line up the corresponding holes in the
braces and back panel and press firmly in place.
PRINTED IN U.S.A.
ELKAY MANUFACTURING COMPANY · 2222 CAMDEN COURT · OAK BROOK, IL 60523 · 630.574.8484
704 . 937. 2673
TROUBLESHOOTING & MAINTENANCE
DESCRIPTION
can cause water flow to spurt or not regulate. Mineral
deposits may be removed from the orifice by poking
with a small round file not over 1/8" diameter, or using a
small diameter wire.
flow as in Step 8 of the installation instructions. If
replacement is necessary, see parts list for correct
regulator part number.
Fittings:
tors which utilize an o-ring water seal. To remove
tubing from the fitting, relieve water pressure, push in
on the gray collar while pulling on the tubing. (See
Figure 15) To insert tubing, push tube straight into
fitting until it reaches a positive stop (approximately 3/4").
35
1/4" O.D. TUBE
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
Page 9
www.RestroomDirect.com
Orifice Assembly: Mineral deposits on orifice
!
CAUTION:
DO NOT file or cut orifice
material.
Stream Regulator: If orifice is clean, regulate
Actuation of Quick Connect Water
Cooler is provided with lead-free connec-
Figure 15 – Quick Connect Fittings
33
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
WATER INLET
TO COOLER
NOTE: WATER FLOW
DIRECTION
Figure 17 – Water Supply Connections
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
97922C (Rev. G - 6/08)