NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which
results in an "electrolysis" effect occurring in the fountain. This may result in water which has a
metallic taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain fittings provided by the installer should be made of plastic which will electronically isolate
the fountain from the remainder of the building's plumbing circuits.
ERPBD28WSC
INSTALLATION & USE MANUAL
Refrigerated fountains with FLEXI-GUARD
®
and ezH2O
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only.
LRPBD2_8WSC
Bottle Filler
®
LZWS-LRPBM28K
Page 1
®
0000001030 (Rev. K - 03/19)
Need help?
Do you have a question about the SWIRLFLO LRPBD2 8WSC Series and is the answer not in the manual?
Questions and answers
Filter status does not reset after filter change
To reset the filter status on the Elkay SWIRLFLO LRPBD2 8WSC Series after a filter change:
1. Press the button until the display shows “SETTINGS.”
2. Wait for approximately 4 seconds until the display changes.
3. Navigate to “FLT SIZE” to select the filter capacity if needed.
4. Locate and select “RST BCNT” to reset the bottle count.
5. The display will return to run mode after the reset is complete.