3/8" O.D. UNPLATED COP-
1/4" O.D. TUBE
PER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
Figure 11 – Water Supply Connections

PARTS LIST

ITEM NO.
PART NO.
1
56073C
Kit - Bubbler Assy
2
55001132
Basin - Swirlflow
3
55000944
Lower Shell
4
45767C
Fountain Body
5
28343C
Cover Plate
6
45781C
Sleeve
7
98871C
Kit - Swirlflo Pushbutton/Spring
8
98530C
Kit - Regulator/Spring/Nut
9
56163C
Gasket - Drain
10
45769C
Assy - Drain/Tailpipe
11
45768C
Drain - Plug 1-1/2"
12
56092C
Poly Tubing (Cut To Length)
13
1000001994
Kit - Tee 1/4 (3 Pack)
14
55996C
Strainer
15
36301C
Reset Switch
16
111008343890
Screw - #10-24 x .62 HHSM
17
70432C
Screw - #8-32 x .38 THSM
18
38417001
Screw - #8-18 x .37 HHSM
19
75560C
Screw - 5/16-18 x 1.00 HHMS
20
75632C
Setscrew - #10-32 x .38
21
1000001772
Kit - Fitting Elbow 1/4 x 1/4 (3 Pack)
22
111577343890
Nut - Hex 5/16-18
23
28395C
Bracket - Support
24
1000002062
Kit - Tee 1/4 x 1/4 x 3/8 (3 Pack)
25
62223C
Copper Tube - 3/8" Cut to Length
26
70852C
Tee - 3/8"
BOTTLE FILLER REPLACEMENT
PART KITS
ITEM NO.
PART NO.
27
98543C
Kit - Electrical Package
28
98544C
Kit - EE Sensor
29
98545C
Kit - Solenoid Valve Replacement
30
98546C
Kit - Aerator Replacement
31
98549C
Kit - Hardware & Waterway Parts
Note: Screw the locknut hand tight to seal
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
EDFPBM117WS
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
DESCRIPTION
DESCRIPTION
Figure 12
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
EDFPBM117WS-F
Installation Package
The components for installation are packed in
two separate boxes, regardless of the type of unit
being installed. The boxes contain the following:
Box No. 1: Wall Frame(s)
Box No. 2: Fountain(s), Arm(s) and Panels
Additional materials, as noted in the Parts List,
are also shipped in these boxes.
TROUBLESHOOTING & MAINTENANCE
Orifice Assembly: Mineral deposits on orifice can
Stream Regulator: If orifice is clean, regulate
flow as in Step 14 of the installation instructions. If
replacement is necessary, see parts list for correct
regulator part number.
Actuation of Quick Connect Water Fittings: Cooler
is provided with lead-free connectors which utilize an
o-ring water seal. To remove tubing from the fitting,
relieve water pressure, push in on the gray collar while
pulling on the tubing. (See Figure 13) To insert tubing,
push tube straight into fitting until it reaches a positive
stop (approximately 3/4").
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A
A
B
B
Figure 13 – Quick Connect Fittings
Page 9
cause water flow to spurt or not
regulate. Mineral deposits may
be removed from the orifice by
poking with a small round file
not over 1/8" diameter, or using
a small diameter wire
.
DO NOT
file or cut orifice
material
TUBE IS SECURED
TUBE IS SECURED
PUSH IN COLLET
PUSH IN COLLET
IN POSITION
IN POSITION
TO RELEASE TUBE
TO RELEASE TUBE
C
C
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
0000001029 (Rev. E - 06/16)

Advertisement

loading