Download Print this page

Parts List; Care And Cleaning Instructions; Troubleshooting And Maintenance - Elkay SWIRLFLO ENOB8C Installation & Use Manual

Refrigerated fountains with flexi-guard

Advertisement

PARTS LIST

ITEM
PART NO.
NO.
1
56073C
Bubbler Assy
2
31272C
Solenoid Valve
3
1000001772
Kit - 70817C Elbow 1/4 Stem x 1/4x90 (3 Pack)
4
75507C
Fttng-1/4 NPTF x 1/4OD
5
70644C
Screw - #6-32 x .50 PHMS
6
15027C
Brkt - Swirlflow
7
28454C
Brkt - Solenoid/Reg/Wire
8
28455C
Assy - Brkt Solenoid/Reg/Wire
9
28708C
Basin - Swirlflow
10
28473C
Lower Shell
11
45767C
Fountain Body
12
28343C
Cover Plate
13
36207C
Wire - Extension
14
36193C
Assy - Sensor Eye
15
45813C
Sleeve - Swirlflow EE
16
50986C
Holder - Regulator
17
61314C
Regulator
18
31376C
Cord - Power 115V
19
56163C
Gasket - Drain
20
0000000930
Assy - Drain/Tailpipe
21
45768C
Drain - Plug 1-1/2"
22
56092C
Poly Tubing (Cut To Length)
23
1000002162
Kit - 70383C Union 1/4 x 1/4 (3 Pack
24
55996C
Strainer (Provided With Chiller)
25
28382C
Back Panel
26
26833C
Lower Panel
27
111008343890
Screw - #10-24 x .62 HHMS
28
70432C
Screw - #8-32 x .38 THTC
29
38417001
Screw - #8-18 x .37 HHSM
30
75560C
Screw - 5/16-18 x 1.00 HHMS
31
40045C
Nut - Hex 1 5/16
32
70022C
Screw - #6-32 x .31 Set
33
70020C
Nut - Hex 5/16-18
34
28395C
Bracket - Support
35
50203C
Bushing - Strain Relief
36
1000001912
Kit - 56082C Regulator Nut (2 Pack)
37
56204C
Lens - Swirlflow EE
Installation Package
The components for installation are packed in three
separate boxes, regardless of the type of unit being
installed. The boxes contain the following:
Box No. 1: Wall Frame(s)
Box No. 2: Remote Chiller, ECH8
Box No. 3: Fountain Arm and Panels
Additional materials, as noted in the Parts List, are also
shipped in these boxes.

CARE AND CLEANING INSTRUCTIONS

DO NOT use abrasive or chemical cleaners to clean the sensor lens.
They may dull the luster and attack the plastic cover and chrome finish
of the fountain. Use ONLY soap and water, then wipe with clean cloth
or towel. When cleaning adjacent surfaces, the fountain and the sen-
sor lens should be protected from any splattering of cleaners. Acid and
cleaning fluids can discolor and damage chrome plating and plastic
sensor lens.
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com
98004C (REV. C - 02/18)
DESCRIPTION
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
ENOB8C
1/4" O.D. TUBE
WATER INLET
TO COOLER
NOTE: WATER FLOW
Figure 11 – Water Supply Connections
Actuation of Quick Connect Water Fittings: Cooler
is provided with lead-free connectors which
utilize an o-ring water seal. To remove tubing
from the fitting, relieve water pressure, push
in on the gray collar while pulling on the
tubing. (See Figure 12) To insert tubing, push
tube straight into fitting until it reaches a
positive stop approximately 3/4")
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A
A
Figure 12 – Quick Connect Fittings
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy: Minerals deposits on orifice can cause water flow to
spurt or not regulate. Mineral deposits may be removed
from the orifice with a small round file not over 1/8" diameter or a
small diameter wire. CAUTION: Do not file or cut orifice materials.
2. Stream Regulator: If orifice is free of material deposits regulate
water flow according to instructions on page 4.
3. Sensor Control: The sensor has a 2 second delay time. If sensor
fails to operate valve mechanism or operates erratically, check
the following:
a) Ensure there are no obstructions within a 40 inch radius from
the front of fountain.
b) Check wire connections at the solenoid valve and at the sensor.
CAUTION: Make sure unit is unplugged before checking any
wiring.
c) Ensure proper operation of solenoid valve. If there is an audible
clicking sound yet no water flows, look for an obstruction in the
valve itself or elsewhere in the water supply line.
WARNING: Do not expose sensor to direct sunlight.
4. Sensor Range Adjustment: The electronic sensor used in this
fountain is factory pre-set for a "visual" range of 36 inches. If
actual range varies greatly from this, or a different setting is desired,
follow the range adjustment procedure below:
a) Remove front lens.
b) Locate range adjustment screw between the lenses of the
sensor, then with a small tip screwdriver, rotate the range adjust-
ing screw clockwise to increase range or counter-clockwise to
decrease range. 1/4 turn of screw is equal to approximately
12 - 18 inches of range.
CAUTION: Complete range of sensor (24 - 46 inches) is only one
turn of the adjusting screw.
c) Replace Lens.
Page 6
3/8" O.D. UNPLATED COP-
BUILDING WATER
PER TUBE CONNECT
COLD WATER SUPPLY
SERVICE STOP
(NOT FURNISHED)
DIRECTION
.
TUBE IS SECURED
TUBE IS SECURED
PUSH IN COLLET
PUSH IN COLLET
IN POSITION
TO RELEASE TUBE
IN POSITION
TO RELEASE TUBE
B
B
C
C
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
INLET