Installation/Care/Use Manual
Soft Sides
Note: Danger! Electric shock hazard. Disconnect power before servicing unit.
Installer
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL
AND OTHER APPLICABLE CODES. After installation, leave these instructions
inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM
THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE IS SECURED
TUBE IS SECURED
TUBE TO ATTACH
TUBE TO ATTACH
IN POSITION
A
A
B
B
FIG. 1
BASIN
FIG. 3
LCRSPD10_2AQ
Refrigerated Fountains
®
USES HFC-134A REFRIGERANT
IMPORTANT
PUSH IN COLLET
PUSH IN COLLET
IN POSITION
TO RELEASE TUBE
TO RELEASE TUBE
C
C
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
29
9
29
9
14
16
29
FIG. 2
PAGE 1
12 8
30 15
22
10
1000002394 (Rev. C - 6/15)

Advertisement

loading

Summary of Contents for Elkay Soft Sides Series

  • Page 1 LCRSPD10_2AQ Installation/Care/Use Manual Soft Sides Refrigerated Fountains ® Note: Danger! Electric shock hazard. Disconnect power before servicing unit. USES HFC-134A REFRIGERANT Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
  • Page 2 LCRSPD10_2AQ 14" 354mm MINMUM DEPTH BACK WALL LINE FINISHED WALL LINE 19-3/4" 502mm 3-3/4" 12-1/8" 3-3/4" 95mm 309mm 95mm 18" 22" 558mm 457mm 31-3/8" 797mm 22-1/4" 28-1/8" 564mm 27" 714mm 686mm ADULT ADA REQUIREMENT 13-5/8" 347mm FINISHED FLOOR 4-1/2" 114mm WALL OPENING 3-7/8"...
  • Page 3 LCRSPD10_2AQ FILTER INSTALLATION INSTRUCTIONS Remove front panel of chiller. Note: For color images please visit www.elkay.com. Install 3/8" formed copper tube (item 4) to left side of filter head. Screw locknut hand-tight to seal. See Figures 5 and 14. Mount filter head to chiller using (3) screws (provided). See Figure 6.
  • Page 4: Installation Instructions

    LCRSPD10_2AQ INSTALLATION INSTRUCTIONS Install mounting frame. See rough-in diagram (Figure 4) and mounting frame installation instructions. Install remote chiller. Verify that filter has been installed inside chiller. Slide chiller onto shelf and center it within the shelf guides. NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. See chiller instructions for additional information.
  • Page 5 FIG. 13 FIG. 14 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 PAGE 5 1000002394 (Rev. C - 6/15)