Abbreviation Command description
SP
SR, #SR
ER, #ER
SW, #SW
EW, #EW
KI
Filter Commands
Abbreviation Command description
FI
MF
Configuration Commands
Abbreviation Command description
RP
WP
6.4
Read/Write Commands
The tag's memory structure is based on the following read/write commands in accordance with
EPC Gen 2 (ISO/IEC 18000-63). See chapter 3.2.3.
Single Read Read-Only Code SF
One attempt is made to read a read-only code (TID). The read-only code is 4, 8, or 12 bytes
long, and comprises a 4-byte part number, which denotes the tag type, and optionally a tag
with a unique serial number of 4 or 8 bytes. Details see chapter 3.2.3.
Command:
Response:
<Length> = Length of the <Fixcode> in ASCII
Example:
SF1 reads the read-only code to IDENTControl channel 1.
Enhanced Read Read-Only Code EF
This command continuously attempts to read a read-only code (TID). If a read-only code is
read, this is reported once. If there is no tag in the detection range, or if the tag leaves the
detection range, a status 5 message is reported.
Command:
Response:
<Length> = Length of the <Fixcode> in ASCII
44
See "Single Write Special Read-Only Code SP" on page 46
See "Single Read Words SR" on page 47
See "Enhanced Read Words ER" on page 47
See "Single Write Words SW" on page 47
See "Enhanced Write Words EW" on page 48
See "Kill UHF Tag KI" on page 48
See "Set Filter Mask FI" on page 49
See "Activate/Deactivate Filter MF" on page 50
See "Read Parameters" on page 55
See "Write Parameters" on page 55
SF <ChanNo> <CHCK> <ETX>
<Status> <ChanNo> <Luii> <UII> <Length>
<Fixcode> <CHCK> <ETX>
F <ChanNo> 0001 <CHCK> <ETX>
hex
EF <ChanNo> <CHCK> <ETX>
<Status> <ChanNo> <Luii> <UII> <Length>
<Fixcode> <CHCK> <ETX>
hex