IUH-F192-V1-*
Commissioning
5.3

Sensor Settings

Warning!
Device not configured or configured incorrectly
Configure the device prior to commissioning. A device that has not been configured or
configured incorrectly may lead to faults in the plant.
Warning!
L'appareil non configuré ou mal configuré
Configurez l'appareil avant de l'utiliser. Un périphérique mal configuré peut provoquer des
erreurs dans le système.
You must configure the control interface before commissioning the IUH-F190-V1-* read/write
head. To do so, refer to the "Commissioning" chapter of the manual for your control interface.
Configure the read/write heads with the described system commands (). For a
parameterization example, see see chapter 5.4.
Caution!
Uncontrolled triggered processes
Before commissioning the device, make sure that all processes are running smoothly;
otherwise damage may occur in the plant.
Caution!
Processus déclenchés incontrôlés
Avant la mise en service de l'appareil, assurez-vous que tous les processus fonctionnent de
manière contrôlée, sinon vous risquez d'endommager le système.
5.4
Operation via the Command Interface
This section shows you how to commission the IUH-F190-V1-* read/write head using an
IDENTControl control interface with serial interface. The commissioning procedure described
relates to the RS-232 interface and involves a PC. The examples include the syntax for coding
the commands and parameters via the Ethernet TCP/IP and PROFIBUS/PROFINET
interfaces. Further details about these codes and the factory settings for your IDENTControl
control interface can be found in the corresponding manual.
The commissioning of the IUT-F190-R4-V1-* read/write head with integrated RS-485 interface
is also carried out using the above commands and parameters. For details regarding the IUT
F190-R4-V1-* read/write head
Example:
In the examples below, the read/write head is connected to channel 1 of the control interface.
The outputs follow the multiframe protocol, see table "Responses Depending on Protocol
Mode QV" on page 61.