IUH-F192-V1-*
Product Description
Number of predefined channels: 4
Programmable channels: 5, 11, 17, 23
Center frequencies: 916.8 MHz, 918.0 MHz, 919.2 MHz, 920.4 MHz
Up to four channels can be parameterized and used in sequence.
Default: dense reader mode on channel 5, 17, 11, 23. See chapter 3.2.6.
3.3.10

Colombia

The regulations for the UHF frequency range in Colombia are the same as the regulations for
the UHF frequency range in the USA. See chapter 3.3.19.
3.3.11
Malaysia
In Malaysia, the use of RFID in the UHF range is regulated as follows:
UHF frequency range: 919 MHz
Radiated power: 6 mW
Channel bandwidth: 500 kHz
Channel spacing: 500 kHz
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
Number of channels: 8
Channels used: 1, 2, 3, ... 8
Center frequencies: 918.75 MHz + (M x 0.5) MHz
All 8 channels are always used.
3.3.12
Morocco
In Morocco, the use of RFID in the UHF range is regulated in accordance with EN 302208:
UHF frequency range: 867.6
Radiated Power: 3
Channel bandwidth: 200 kHz
Channel spacing: 200 kHz
Frequency access method: programmable frequency list.
Number of predefined channels: 1
Programmable channels: 1, 2
Center frequencies: 867.7 MHz, 867.9 MHz
Up to two channels can be parameterized simultaneously and used in sequence.
Default: dense reader mode on channel 1, 2. See chapter 3.2.6.
3.3.13
Mexico
The regulations for the UHF frequency range in Mexico are the same as the regulations for the
UHF frequency range in the USA. See chapter 3.3.19.
3.3.14
New Zealand
In New Zealand, the use of RFID in the UHF range is regulated as follows:
UHF frequency range: 921.5 MHz
Radiated power: 10 mW
Channel bandwidth: 500 kHz
20
923 MHz
2000 mW
; Default = 500 mW
ERP
868.0 MHz
500 mW
; Default = 50 mW
erp
928 MHz
4000 mW
; Default = 800 mW
EIRP
(IUH-F192-V1-FR2)
ERP
erp
(IUH-F192-V1-FR2)
EIRP