Message
NT •••.•
ON LINE xx. LOG IN xx. ACTIVE xx.
OPERATOR DROP.
OUTPUT FILE BAD.
OUTPUT FILE RELEASED.
OUTPUT FILE RELEASED.
OVERCOMMITMENT ALGORITHM ERROR.
PACKNAME (packnam) LOADED.
PAGING COMPLETE.
PARITY ERR (filenam) (user index).
PARITY ERROR IN CATALOG IMAGE RECORD.
PERMANENT DAYFILE LIST COMPLETE.
Routine
DSD
(operator message)
PFU
(dayfile message)
REC
(dayfile message)
DFTERM
(operator message)
QREC
(operator message)
RESEX
"(dayfile message)
PFLOADl
(operator message)
QREC
(operator message)
PFLOADl
(dayfile message)
PFLOADl
(dayfile message)
DFTERM
(operator message)
Description
Refer to the EQ. • •• series of corresponding messages for
full descriptions of messages beginning with NT.
Informative message indicating activity at EXPORTLS
control point. This message appears at the EXPORTLS
control point on the DSD job status (B) display.
Informative message indicating that the operator has
dropped the job. Probable cause for dropping the
job was that PFU was unable to clear the utility inter-
lock. Note that the site analyst should be informed
before the job is dropped.
System sector of output file is in error; file is purged.
Informative message on K-display indicating output file was
released to the printer.
An informative message on the K-display indicating the OUT
command has completed.
Resource execution error was encountered; overcom-
mitment algorithm has failed internally. This could
occur when no equipment is available to honor a request.
Informative message indicating auxiliary device, identi-
fied by (packnam), has been loaded.
Informative message on the K-display indicating page advanc-
ing command
(+)
has completed.
Parity error was encountered on tape while loading file
(filenam); file is skipped. This is a nonfatal system
error.
Parity error was detected while reading the image of the
catalog tracks for the device to be loaded from the ar-
chive tape.
K-display message indicating the permanent dayfile list has
written to output for DFLIST or to the K display buffer for
DFTERM.
Action
None.
None.
None.
None.
None.
Inform site analyst.
None.
None.
Same situation as NO DATA
BLOCK depending upon when
error was encountered. Re-
try or use backup tape.
Retry or use backup tape.