If
neither T nor VSN parameter is specified, a flashing REQUEST message for file lfn
appears on the B display and the operator must assign tape unit to control point
indicated.
If
a common file already exists with the same name as specified by lfn,
the system issues the following message.
DUPLICATE COMMON FILE NAME.
If
staging -is done using the K display (Figure 7-1), enter X. STAGE. and then enter
K, n. where n is the control point requesting the K display.
To enter options via the
K display, type K. and the desired options followed by a period.
Only one line of
parameters may be entered; therefore, all desired options must be entered at once,
separated by commas.
7-2
TAPE STAGING OPERATIONS
OPTIONS.
NR = NO REWIND BEFORE COpy
NU = NO UNLOAD AFTER COpy
N = X. X= NUMBER OF FILES TO COpy
DR = DROP JOB AFTER COpy
VSN = X. X= VOLUMN SERIAL NUMBER
F=X. X= TAPE FORMAT
D = X. X= DENSITY
MT/NT
7/9 TRACK
T = X. X= EST ORDINAL. F= X ONLY.
ENTER FILE NAME AND OPTIONS
Figure
7-1.
STA GE Utility K Display