Control Data Cyber 170 Series Operator's Manual page 192

Nos 1.0
Table of Contents

Advertisement

td
I
fl:::.
0')
o
fl:::.
CJ:)
c.n
0')
o
o
~
Message
CANNOT ALLOCATE DEVICE
CATALOG CONTROL WORD MISSING.
CATALOG INDEX OUT OF RANGE.
CATALOG TRACK NOT FOUND.
CHECK DAYFILE FOR ERRORS.
CLEANUP SALVARE FILE.
CMR OVERFLOW.
CMRDECK NOT ON TAPE.
CONTINUING DESTROYS MID=id DAYFILES,
TYPE GO TO PROCEED.
COMPLETE.
Routine
MSI
(operator message)
PFLOADl
(dayfile message)
PFDUMPI
(dayfile message)
PFU
(dayfile message)
PFLOADl
PFDUMPI
(operator message)
TELEX2
(dayfile message)
SET/ICM
(operator message)
SET
(operator message)
RMS
(operator message)
TELEX2
(dayfile message)
Description
Cannot allocate a multispindle device for one of the
following reasons:
1.
Not enough spare spindles available
2.
Spare spindles not up and allocatable.
3.
An attempt was made to allocate a non-
removable device.
Either the catalog. control word was not the initial control word
on the archive file, or the entire catalog entry is not present.
This is a nonfatal system error and is accompanied by the
message TAPE ERROR (filenam) (user index).
Location of catalog buffer is not in buffer range. This is a
fatal system error; PFDUMP aborts.
No permanent file device could be found for the user index
being processed.
Informative message indicating that the utility has generated
dayfile messages which should be brought to the attention of
the operator.
Informative message indicating that TELEX has begun to
release all system resources currently assigned to terminals
in the recovery state. This occurs only when TELEX is
dropped (1. STOP. command).
Address
of
the FNT/FST (file name/file status table) is
greater than 12 bits.
The CMRDECK number specified on bits 3 through 8 of word
13 on the deadstart panel is not contained on the deadstart
tape being used.
Dayfiles have been found on a device which was used by a
machine having a different machine identification than that of
the current system. These dayfiles may be saved by run-
ning the device on a machine with
a
matching machine
identification, or simply discarded.
id
Machine identification
Informative message indicating that TELEX termination is
complete.
Action
Perform one of the following:
1. Decrease pack count and
enter GO.
2. Enter CLEAR to clear
initialize status for the
device.
Retry or use backup tape.
Retry PFDlJMP operation.
Inform site analyst.
Examine error messages in
dayfile.
None.
Inform site analyst.
Redeadstart and select correct
CMRDECK number via deadstart
panel switches or deadstart op-
tions display.
Inform site analyst; recOOlmended
action is:
1.
Redeadstart with proper machine
identification to retain the day-
files, or
2.
Type GO to discard dayfiles.
Deadstart continues and dayfiles
are lost.
None.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cyber 170 Series and is the answer not in the manual?

Questions and answers

Table of Contents