Technibel KPSW 2 Installation Instructions Manual page 12

Floor or ceiling type terminal units

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
F
DEcLaratIon oF conForMItY
This product is marked
GB
– Low voltage no. 006/95/EC (Standard: EN60335--40:003 (incl. Corr.:006) + A11:004 + A1:005 + A13:01
+ A1:006 + A:009 con EN 60335-1:00 + A11:004 + A1:004 + A1:006 + A:006 + A13:008 + A14:010 +
A15:011).
I
– Electromagnetic compatibility no. 004/108/EC, 9/31 EEC and 93/68 EEC. (Standard: EN55014-1 (006) + A1(009)
+ A(011), EN 55014- (1997) + A1(001) + A (008), EN 61000-3- (006) + A1(009) + A(009), EN 61000-3-3
E
(008)
– RoHS no.011/65/EU.
D
contEnts
1 - GEnEraL
1.1 - ForEworD
The equipment must be installed, started-up and maintained
by authorised and qualified personnel, in accordance with
local rules and professional standards.
1.2 - GEnEraL sUppLY conDItIons
Generally speaking, the material is transported at the
consignee's risk.
The consignee must immediately provide the carrier with
written reserves if he finds any damage caused during
transport.
1.3 - voLtaGE
Before any operation, check that the voltage and the
frequency indicated on the device corresponds with that
of the mains.
2 - prEsEntatIon
• See technical documentation.
2.1 - DEscrIptIon
2
3
4
1
5

as it satisfies Directives:
1 - General ................................................................................. 
 - Presentation ......................................................................... 
3 - Installation ............................................................................ 3
4 - Connections / Wiring diagrams ............................................. 7
5 - Accessories .......................................................................... 9
6 - Starting ................................................................................. 9
7 - Maintenance ......................................................................... 9
1 - Air inlet (suction)
2 - Air outlet (blowing)
3 - Vertical deflection louvre
4 - Horizontal deflection louvre
5 - Air filters
1.4 - prEcaUtIons
1.4.1 - HYDraULIc cIrcUIt
- Minimum water inlet temperature : 4°C.
- Maximum water inlet temperature : 60°C.
- Maximum operating pressure
1.4.2 - aMBIEnt aIr
- Minimum air recirculation temperature : 5°C.
- Maximum air recirculation temperature : 3°C.
Important: During installation shut-down, in case of ambient
temperature near 0°C, there is a risk that the hoses may freeze.
Envisage draining the hydraulic circuit.
1.5 - UsE oF EqUIpMEnt
This equipment is intented for the air-conditioning of
premises and to provide comfort for the personnel.
1.6 - MoDELs
"-pipe" for all sizes.
3
4
2
1
Materials:
: 16 bar.
5
• Painted metal frame.
• Plastic body.
• Copper pipping.