Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper inter-
pretation of these symbols will allow you to operate the product better and safer.
SYMBOL
VAC
Voltage Alternating Current
VDC
Voltage Direct Current
A
Amperes
Hz
Hertz
Watt
W
min
Minutes
OGI PART# 460346 Solar Powered Control Panel
Nominal System Voltage: 12 VDC
Rated Solar Input: 6A
Max. Solar Voltage: 30 VDC
Regulation Voltage: 14.1 VDC at 25°C
OGI PART# 460347 VAC Powered Control Panel
Nominal System Voltage: 85 - 264 VAC
Rated Current Input: 1.35A at 120 VAC/0.65A at 230 VAC
OGI PART# 460348 VDC Powered Control Panel
Nominal System Voltage: 12-24 VDC
Rated Current Input: 2.3-1.1A
OGI PART# 452024 Ignition Module
Flame Sensing Method: Flame Ionization
Ignition Module Input Voltage: 11.5 – 13.5 VDC
Max Current Draw: 220 mA
Stand-By Current Draw: 63 mA (Flame On monitoring)
Stand-By Current Draw: 26 mA (System is On waiting on start signal)
Current Draw values dependent on solenoid valve selection (11.6 W MAX ALLOWED)
Ignition Wire Properties:
Maximum Length: 20 ft
Operating Temperature Rating: -40°F to 175°F
Read installation instructions for important information on ignition Wire installation details.