Part 6 Troubleshooting - Daikin VRV II RXYQ5MATL Service Manual

R-410a heat pump 60hz
Table of Contents

Advertisement

Si39-504
1. Symptom-based Troubleshooting .......................................................154
2. Troubleshooting by Remote Controller ...............................................157
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
2.1 The INSPECTION / TEST Button.........................................................157
2.2 Self-diagnosis by Wired Remote Controller .........................................158
2.3 Self-diagnosis by Wireless Remote Controller .....................................159
Test Operation Button ..........................................................................162
2.5 Remote Controller Service Mode .........................................................163
2.6 Remote Controller Self-Diagnosis Function .........................................165
3.2 "A1" Indoor Unit: PC Board Defect.........................................................171
Electronic Expansion Valve (20E) ........................................................177
3.7 "AF" Indoor Unit: Drain Level above Limit..............................................179
Heat Exchanger....................................................................................181
Remote Controller ................................................................................184
3.13 "E1" Outdoor Unit: PC Board Defect ......................................................185
3.16 "E5" Outdoor Unit: Compressor Motor Lock ..........................................188
Electronic Expansion Valve (Y1E, Y2E)...............................................192
3.21 "F6" Outdoor Unit: Refrigerant Overcharged.........................................195
3.24 "J2" Outdoor Unit: Current Sensor Malfunction ....................................198
(R3, R31~33T) .....................................................................................199
Outdoor Unit Heat Exchanger Deicer...................................................201
3.28 "J7" Outdoor Unit: Malfunction of Receiver Outlet Liquid
Pipe Thermistor (R6T)..........................................................................202
Part 6
Part 6
Part 6
Part 6
151

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrv ii rxyq8matlVrv ii rxyq8maylVrv ii rxyq5maylVrv ii rxyq5mayleVrv ii rxyq8mayleVrv ii rxyq5matle ... Show all

Table of Contents