Technical Data - Immergas VICTRIX EXA 28 1 ERP Instruction And Recommendation Booklet

Table of Contents

Advertisement

3.20 TECHNICAL DATA.

Domestic hot water nominal heat input
Central heating nominal heat input
Minimum heat input
Domestic hot water nominal heat output (useful)
Central heating nominal heat output (useful)
Minimum heat output (useful)
* Effective thermal efficiency 80/60 Nom./Min.
* Effective thermal efficiency 50/30 Nom./Min.
* Effective thermal efficiency 40/30 Nom./Min.
Casing losses with burner On/Off (80-60°C)
Heat loss at flue with burner On/Off (80-60°C)
Central heating circuit max. operating pressure
Maximum heating temperature
Adjustable central heating temperature
System expansion vessel total volume
Expansion vessel factory-set pressure
Appliance water content
Head available with 1000 l/h flow rate
Hot water production useful heat output
Domestic hot water adjustable temperature
Domestic hot water circuit min. pressure (dynamic)
Domestic hot water circuit max. operating pressure
Minimum D.H.W. flow rate
Flow rate capacity in continuous duty (∆T 30°C)
Weight of full boiler
Weight of empty boiler
Electrical connection
Nominal power absorption
Installed electric power
Pump absorbed power
Fan power absorbed power
Pump system EEI value
Equipment electrical system protection
Max temperature of combustion products
NO
class
X
Weighted NO
X
Weighted CO
Type of appliance
Category
- The data relating to domestic hot water perfor-
mance refer to a dynamic inlet pressure of 2 bar
and an inlet temperature of 15°C; the values
are measured immediately at the boiler outlet,
considering that to obtain the data declared,
mixing with cold water is required.
- * Efficiencies refer to the net calorific value.
Victrix EXA 28 1 ErP
kW (kcal/h)
28.4 (24408)
kW (kcal/h)
24.2 (20785)
kW (kcal/h)
5.7 (4866)
kW (kcal/h)
27.7 (23822)
kW (kcal/h)
23.7 (20382)
kW (kcal/h)
5.5 (4730)
98.1 / 97.2
%
%
106.0 / 106.5
107.2 / 107.8
%
%
0.47 / 0.6
0.01 / 1.8
%
bar
°C
°C
l
bar
l
kPa (m H
O)
29.6 (3.0)
2
kW (kcal/h)
27.7 (23822)
°C
bar
bar
l/min
l/min
kg
kg
V/Hz
230 / 50
A
W
W
W
-
≤ 0.20 - Part. 3
-
°C
-
mg/kWh
mg/kWh
C13 / C13x / C33 / C33x / C43 / C43x / C53 / C63 / C83 / C93 / C93x / B23p / B33
34
Victrix EXA 32 1 ErP
32.5 (27939)
28.4 (24411)
7.4 (6403)
32.0 (27520)
28.0 (24080)
7.2 (6192)
98.6 / 96.7
108.0 / 105.9
109.0 / 106.0
0.26 / 0.3
0.01 / 1.2
3.0
3.0
90
20 - 85
20 - 85
5.0
5.0
1.0
1.0
3.4
3.1
29.6 (3.0)
32.0 (27520)
30 - 60
30 - 60
0.3
0.3
10.0
10.0
1.5
1.5
13.7
15.3
40.4
42.1
37.0
39.0
230 / 50
0.56
0.62
76
40
22
≤ 0.20 - Part. 3
IPX5D
IPX5D
75
5
41
14
II 2H3B/P
90
90
56
17
75
5
36
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Victrix exa 32 1 erp

Table of Contents