1.5 HYDRAULIC CONNECTION.

Attention: in order not to void the condensa-
tion module warranty, before making the boiler
connections, carefully wash the heating system
(pipes, radiators, etc.) with special pickling or
descaling products to remove any deposits that
could compromise correct boiler operation.
A chemical treatment of the heating and water
system water is required, in compliance with the
technical standards in force, in order to protect
the system and the appliance from deposits (e.g.
scale), slurry or other hazardous deposits.
Water connections must be made in a rational
way using the couplings on the boiler template.
The boiler safety valve outlet must be connected
to a draining funnel. Otherwise, the manu-
facturer declines any responsibility in case of
flooding if the drain valve cuts in.
Attention: Immergas declines all liability in the
event of damage caused by the inclusion of auto-
matic filling that is not its own brand.
In order to meet the system requirements es-
tablished by the technical regulation in force in
relation to the pollution of drinking water, we
recommend installing the IMMERGAS anti-
backflow kit to be used upstream of the cold
water inlet connection of the boiler. It is also
recommended that the heat transfer fluid (e.g.
water + glycol) entered in the primary circuit
of the boiler (heating circuit), complies with the
local regulations in force.
Attention: to preserve the duration and the ef-
ficiency features of the appliance, in the presence
of water whose features can lead to the deposit of
scale, installation of the "polyphosphate dispenser"
kit is recommended.
Condensate drain. To drain the condensate
produced by the appliance, it is necessary to
connect to the drainage system by means of acid
condensate resistant pipes, with an internal Ø of
at least 13 mm. The system connecting the appli-
Attention: when installing the connection kit (optional), it is compulsory
to insert a flat gasket on the gas and hot water outlet fittings.
Key:
V - Electrical connection
1 - Filling cock
2 - Draining valve
ance to the drainage system must be carried out
in such a way as to prevent freezing of the liquid
contained in it. Before appliance ignition, ensure
that the condensate can be correctly removed.
After first ignition, check that the drain trap is
filled with condensate (para. 1.21). Also, comply
with national and local regulations on discharg-
ing waste waters. In the event condensate is not
discharged into the wastewater drainage system,
a condensate neutraliser must be installed to en-
sure compliance with the parameters established
by the legislation in force.

1.6 ELECTRICAL CONNECTION.

The "Victrix EXA 28 1 ErP - 32 1 ErP" boiler
has an IPX4D protection rating for the entire
appliance. Electrical safety of the appliance is
reached only when it is correctly connected to an
efficient earthing system as specified by current
safety standards.
Attention: Immergas S.p.A. declines any respon-
sibility for damage or physical injury caused by
failure to connect the boiler to an efficient earth
system or failure to comply with the reference
standards.
• Open the control panel connections compart-
ment (Fig. 1-4).
To carry out electrical connections, all you have
to do is open the connections compartment as
follows.
- Disassemble the grid (Fig. 3-5a).
- Remove the caps, loosen the fastening screws
and pull the front panel (c) towards you (Fig.
3-5b).
- Remove the cover (b fig. 1-4).
1) Loosen the screws (a).
2) Remove the cover (b) from the control
panel (c).
- At this point, it is possible to access the terminal
board (d).
1
2
1
V
1-3
7
Also ensure that the electrical installation cor-
responds to maximum absorbed power specifi-
cations as shown on the boiler data nameplate.
Boilers are supplied complete with an "X" type
power cable without plug. The power supply
cable must be connected to a 230V ±10% / 50Hz
mains supply respecting L-N polarity and earth
connection;
, this network must also have a
multi-pole circuit breaker with class III over-
voltage category. When replacing the power
supply cable, contact a qualified firm (e.g. the
Authorised After-Sales Technical Assistance
Service). The power cable must be laid as shown
(Fig. 1-3).
In the event of mains fuse replacement on the
P.C.B., use a 3.15A quick-blow fuse. For the main
power supply to the appliance, never use adapt-
ers, multiple sockets or extension leads.
Installation with system operating at direct
low temperature. The boiler can directly feed a
low-temperature system by acting on parameters
"S5" and S6" (par. 3.8). In this situation it is good
practice to insert a relevant safety kit (optional)
made up from a thermostat (with adjustable
temperature). The thermostat must be positioned
on the system flow pipe.
a
1
a
b
2
c
d
e
1-4