FOR QUALIFIED INSTALLER ONLY. This basic Installation Sheet is an initial release. If a complete Operations
Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for
immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate
access to other Technical Documents and alternative translations (if available) pertaining to this unit. Contact Lancer
Customer Service for assistance as required.
ABOUT THIS MANUAL
This booklet is an integral and essential part of the product and
should be handed over to the operator after the installation and
preserved for any further consultation that may be necessary.
Please read carefully the guidelines and warnings contained
herein as they are intended to provide the user with essential
information for the continued safe use and maintenance of the
product. In addition, it provides GUIDANCE ONLY to the user on
the correct services and site location of the unit.
The installation and relocation, if necessary, of this product must be carried out by qualified personnel with
up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

IMPORTANT SAFETY INSTRUCTIONS

! Intended Use
The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should
not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance
shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to
90°F (4°C to 32°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of
the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained
personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.
F Electrical Warning
Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.
into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local
electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with
this unit. Do not 'gang' together with other electrical devices on the same outlet. The keyswitch does not disable the line voltage to
the transformer primary. Always disconnect electrical power to the unit to prevent personal injury before attempting any internal
maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source
to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all
water lines are tight and units are dry before making any electrical connections!
MCY-22
MCY-30
Bevariety™ ACIB Dispenser 22"/30"/44"
BEFORE GETTING STARTED
Each unit is tested under operating conditions and is thoroughly
inspected before shipment. At the time of shipment, the carrier
accepts responsibility for the unit. Upon receiving the unit,
carefully inspect the carton for visible damage. If damage exists,
have the carrier note the damage on the freight bill and file a
claim with carrier. Responsibility for damage to the dispenser lies
with the carrier.
LANCER INSTALLATION GUIDE
Do not plug
LANCER PN: 28-0953/02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bevariety ACIB Series and is the answer not in the manual?

Questions and answers

Summary of Contents for lancer Bevariety ACIB Series

  • Page 1: Important Safety Instructions

    FOR QUALIFIED INSTALLER ONLY. This basic Installation Sheet is an initial release. If a complete Operations Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate access to other Technical Documents and alternative translations (if available) pertaining to this unit.
  • Page 2: Specifications And Features

    5 Carbon Dioxide (CO • WARNING: Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO displace oxygen in the blood. • WARNING: Prolonged exposure to CO can be harmful. Personnel exposed to high concentrations of CO gas will experience tremors which are followed by a loss of consciousness and suffocation.
  • Page 3: Unit Overview

    READ THIS MANUAL This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your Lancer Service Agent or Lancer Customer Service.
  • Page 4: Pre-Installation

    ! ATTENTION bucket (a minimum of 16 inches is recommended). NOTE DO NOT LAY UNIT ON ITS SIDE OR BACK Lancer does NOT recommend the use of shaved or Inspection of Drain Spider flake ice in the dispenser. NOTE The drain spider is located directly in the center of the MINIMUM of 6"...
  • Page 5: Dispenser Installation

    An adapter plate is required when installing an icemaker. Contact your Sales Representative or Lancer Customer Ensure the icemaker is installed properly to allow for removal Service for more information. of the Merchandiser.
  • Page 6 Remote Pump Installation Connect a 1/4” nut, stem and seal to CO regulator outlet. If necessary, install water booster (Lancer PN MC-163172) Route appropriate tubing from the low pressure CO between water supply and the unit. regulator manifold location to the 1/4” nut, stem on the high...
  • Page 7: Dispenser Setup

    Using a wrench, loosen lock nut on the regulator adjustment Test the motor operation by pushing the ice chute lever until screw of the high pressure CO regulator connected to the agitator motor begins to turn. source, then using a screwdriver back out lock nut screw all Activate each valve to ensure a good flow of water is the way.
  • Page 8 40°F (4.4°C) when flow rates are set. Remove valve cover from first valve. Close syrup shut-off at mounting block for first LEV. Using a Lancer ratio cup verify water flow rate (5 oz. in 4 sec.). Use a screwdriver to adjust if needed. A. Syrup Seperator B.
  • Page 9 PROGRAMMING AND MAINTENANCE - MVU Adjust Water Flow Rate & Syrup/Water Ratio - MVU Repeat process for each brand on the MVU, then press the Save button to save the programming. NOTE The MVU can be programmed to serve carbonated or non-carbonated beverages as well as a flavor shot from each of the beverage positions on the valve.
  • Page 10 Using the Lancer ratio cup, verify that 10 oz. of water was dispensed. Use screwdriver to adjust appropriate LFCV if needed. Increase Decrease A. Flow Control B. Valve Retainer C. Solenoid D. Valve Body Remove nozzle and install MVU syrup separator in place of Approximately 10 ml should dispense, if not, use a screw nozzle.
  • Page 11: Cleaning And Sanitizing

    General Information Cleaning Solution • Lancer equipment (new or reconditioned) is shipped from Mix a mild, non-abrasive detergent (e.g. Sodium Laureth the factory cleaned and sanitized in accordance with NSF Sulfate, dish soap) with clean, potable water at a temperature guidelines.
  • Page 12: Ice Bin Cleaning - Start-Up And Monthly

    Ice Bin Cleaning - Start-Up and Monthly 11. Taste the drink to verify that there is no off-taste. If off-taste is found, flush syrup system again. NOTE ! CAUTION Refer to the Automatic Agitation Warning on page 3. Following sanitization, rinse with end-use product until there is no aftertaste.
  • Page 13: Cleaning And Sanitizing Nozzles

    Cleaning and Sanitizing Nozzles Ice Chute Cleaning NOTE Disconnect power, so as to not activate valve while cleaning. Remove nozzle by twisting counter clockwise and pulling It is recommended to perform this procedure monthly, down. or more often if desired. Use the cleaning solution described above.
  • Page 14 WIRING DIAGRAMS - ACIB 22”,30”...
  • Page 15 PLUMBING DIAGRAMS - ACIB 22”,30”...
  • Page 16 Lancer Corp. 800-729-1500 Technical Support/Warranty: 800-729-1550 custserv@lancercorp.com lancercorp.com...