4 INSTALLATION

4
INSTALLATION
Installation may only be carried out by trained personnel. These trained personnel must be familiar
with the general safety regulations that are applicable for installation and operation of opto-
mechatronic systems, machines and plants.
4.1

Safety during installation

Hazard due to electrical energy
The deflection unit is designed for intended operation on a safety extra-low voltage (< 60 V DC). The
operator is responsible for safe provision of the power supply (voltage limitation, shutdown on
overcurrent, line protection).
 Make sure that the power supply does not exceed the specified low voltage.
 During all work on the electrical power supply and the electrical systems, observe the relevant
electrical safety regulations.
Risk of injury due to laser radiation
The laser beam (including a reflected beam) can cause severe injuries to the eyes and skin.
 The laser system may only be installed and started up by trained personnel.
 After all work, ensure that the laser system is switched off and secured against being switched
on again.
Risk of injury due to falling deflection unit
A falling deflection unit can cause injuries.
 The deflection unit should be installed by two people wearing suitable safety shoes.
© 2017 RAYLASE GmbH MINISCAN II
WARNING
C 3-0 10. 1
WARNING
C2 -01 0
WARNING
C2 -030
MN102-en / v1.0.3
22