Technical Data - RAYLASE MINISCAN II-07 Manual

2-axis deflection units
Table of Contents

Advertisement

3 PRODUCT DESCRIPTION
3.6

Technical data

3.6.1
General specifications
Typical deflection
Resolution
Repeatability (RMS)
Max. Gain drift
Max. Offset drift
Long-term drift 8 h
IP-Code
Emission sound pressure level
1) Drift per axis.
2) After 30 min warm-up, at constant ambient temperature and process stress.
Remark: All angles optical.
3.6.2
Power supply
Voltage
Current
Ripple/ Noise
3.6.3
Control signals
Analogue
Digital
3.6.4
Ambient conditions
Ambient temperature at operation
Storage temperature
Humidity
© 2017 RAYLASE GmbH MINISCAN II
1
1
1, 2
MN102-en / v1.0.3
±0.393 rad
12 μrad
2 μrad
15 ppm/K
10 μrad/K
<150 μrad
54
<70 dB(A)
±15 to ±18 V
2 A, RMS, max. 10 A
Max. 200 mVpp, @ 20 MHz bandwidth
±5 V, ±10 V
XY2-100 protocol
+15 to +35 °C
-10 to +60 °C
≤ 80 % non-condensing