Appendix 3: Setting Source Turn-On Volume for IR Switching Mode Operation

The installer/user can set the turn-on volume for the Local (B) source when using IR commands. (Previously, the volume always
started at zero each time the amplifier switched to the Local source, and the user would have to use jump or
volume-up IR commands to bring the amplifier to the desired volume.)
N
: T
O T E
H I S F U N C T I O N O N LY A F F E C T S O P E R AT I O N W H E N T H E
T o s e t t h e L o c a l s o u r c e t u r n - o n v o l u m e :
1. Trigger the amplifier so it switches to the Local source input by using Audio + IR, Voltage + IR, AC + IR or IR triggering.
2. With a keypad or via an IR receiver, use IR volume jump or step-up commands to bring the volume to the desired turn-on
level.
3. Press-and-hold the front-panel STBY button for five seconds. The House LED will blink twice to signal that the turn-on
volume level has been stored.
4. Any time the amplifier is triggered to the Local source input the volume will start at the volume level set in memory.
T o s e t t h e v o l u m e l e v e l b a c k t o z e r o ( f a c t o r y d e f a u l t ) ) :
1. Unplug the amplifier's power cord from the back of the amplifier or wall outlet.
2. Press-and-hold the front-panel AC S

Appendix 4: Front-Panel LED Fault Indications

H
LED Action
OUSE
1 Flash every 5 seconds
1 Flash every 2 seconds
2 Flashes every 2 seconds
3 Flashes every 2 seconds
*If the amplifier goes into Over-Current or Short-Circuit protection 5 times in 1 minute it will shut-down. After correcting the over-current
condition (speaker impedance too low, volume too high, short-circuit, etc), unplug the AC cord, wait 10 seconds, then plug the AC cord back in.
14
P
A
T E R E O
O W E R
M P L I F I E R
button while plugging-in the power cord.
ENSE
Cause
Amplifier is in S
mode
TANDBY
More than 1 Trigger Mode switch
(A
, V
, AC) is set to ON
UDIO
OLT
Over-Temperature
Over-Current; Short-circuit in
speaker output
I R T
D I P
R I G G E R
S W I T C H I S S E L E C T E D
Condition
Amplifier will not switch to
L
source
OCAL
Amplifier output muted
Amplifier output muted
Amplifier output mutes for
5 seconds, then turns back ON
(
7 ) .
S E E PA G E
Remedy
Press front-panel STBY button
Set only 1 A
, V
or AC Trigger Mode
UDIO
OLT
switch to ON
Unplug the AC cord, wait 30 seconds,
then plug the AC cord back in
No action necessary if the amplifier remains
ON*