Interfaces and Terminals – Assignments
Table B-4
Assignment of the Terminal Strips, continued
No.
Terminal Strip X4
1
"EMERGENCY STOP" switch, Terminal 22
2
"EMERGENCY STOP" switch, Terminal 21
3
"EMERGENCY STOP" switch, Terminal 32
4
"EMERGENCY STOP" switch, Terminal 31
5
–
6
Terminal Strip XL/M, Terminal 15
7
Enabling switch, Pin 10
8
Enabling switch, Pin 11
9
Enabling switch, Pin 12
10
Enabling switch, Pin 13
11
Enabling switch, Pin 14
12
Enabling switch, Pin 15
13
–
14
–
15
–
16
–
17
–
18
–
19
–
20
–
Terminal Strip X2
L1
230 V AC external supply (hot) –> SIMATIC Box PC 820, mains connection
L2
230 V AC (hot)
N1
230 V AC external supply (neutral) –> SIMATIC Box PC 820, mains connection
N2
230 V AC (neutral)
PE1
Protective earth external supply –> SIMATIC Box PC 820, mains connection
PE2
Protective earth –> enabling switch, Pin 17 (1.5 mm
PE3
Protective earth –> ground for terminal strip rail (1.5 mm
PE4
Protective earth –> ground for the hinged plate (1.5 mm
PE5
Protective earth –> ground for front of housing (1.5 mm
PE6
External functional ground –> ground for SIMATIC Box PC 820 (6 mm
Caution
!
On the terminal strips XL/M and X4, connect only SELV voltages (safety
extra-low voltage).
To connect lines with a cross-section of up to 0.74 mm
B-4
Usage/Description
2
)
2
)
2
)
2
)
SICALIS PMC 7 Operator Panel Equipment Manual
2
)
2
, use wire end ferrules.
Release 09/00