Siemens SIMATIC HMI SICALIS PMC 7 Equipment Manual page 44

Table of Contents

Advertisement

Interfaces and Terminals – Assignments
Table B-4
Assignment of the Terminal Strips, continued
No.
Terminal Strip X4
1
"EMERGENCY STOP" switch, Terminal 22
2
"EMERGENCY STOP" switch, Terminal 21
3
"EMERGENCY STOP" switch, Terminal 32
4
"EMERGENCY STOP" switch, Terminal 31
5
6
Terminal Strip XL/M, Terminal 15
7
Enabling switch, Pin 10
8
Enabling switch, Pin 11
9
Enabling switch, Pin 12
10
Enabling switch, Pin 13
11
Enabling switch, Pin 14
12
Enabling switch, Pin 15
13
14
15
16
17
18
19
20
Terminal Strip X2
L1
230 V AC external supply (hot) –> SIMATIC Box PC 820, mains connection
L2
230 V AC (hot)
N1
230 V AC external supply (neutral) –> SIMATIC Box PC 820, mains connection
N2
230 V AC (neutral)
PE1
Protective earth external supply –> SIMATIC Box PC 820, mains connection
PE2
Protective earth –> enabling switch, Pin 17 (1.5 mm
PE3
Protective earth –> ground for terminal strip rail (1.5 mm
PE4
Protective earth –> ground for the hinged plate (1.5 mm
PE5
Protective earth –> ground for front of housing (1.5 mm
PE6
External functional ground –> ground for SIMATIC Box PC 820 (6 mm
Caution
!
On the terminal strips XL/M and X4, connect only SELV voltages (safety
extra-low voltage).
To connect lines with a cross-section of up to 0.74 mm
B-4
Usage/Description
2
)
2
)
2
)
2
)
SICALIS PMC 7 Operator Panel Equipment Manual
2
)
2
, use wire end ferrules.
Release 09/00