Siemens SIMATIC HMI SICALIS PMC 7 Equipment Manual page 37

Table of Contents

Advertisement

Display
LCD type
Active screen diagonal
Resolution (pixels) horizontal x vertical
Graphic mode
Service life (MTBF)
Backlighting
Service life (MTBF)
4)
Depending on the operating temperature, the lamps for the display's backlighting have a
service life of around 30,000 hours. In unfavorable operating conditions, we recommend
that the tubes are replaced after that period. The tubes are available as spare parts. If
one tube fails it is advisable to replace both at the same time in order to ensure even
illumination.
Controls
Sealed membrane keyboard
Movement keys
Function keys with programmable
functions
30 mm elements, recessed design
Rotary switch, 10steps
Key-operated switch/button
Illuminated pushbutton
Pushbuttons
Emergency Stop
Power Supply
Alternating current
(for SIMATIC Box PC 820)
– Frequency
– Maximum power consumption
Direct current
– Rated voltage
– Permissible range
– Max. permissible transients
– Time between two transients
– Current consumption
Typically
Maximum continuous current
– Switch-on surge
– Circuit breaker, internal
5)
Not electrically isolated (see notes on page 2-6).
SICALIS PMC 7 Operator Panel Equipment Manual
Release 09/00
4)
5)
2
t
TFT (active matrix display)
12.1''
800 x 600
Super VGA
Approx. 50,000 h
2 CCFL tubes
Approx. 30,000 h
16 (2 x 8)
16
MOP
1
1/1
6
2
1
switchable between
115 V AC (93...132 V AC)
230 V AC (187..264 V AC)
50 Hz (47...63 Hz)
220 W
+24 V DC
+18.0...+30.0 V DC
35 V (500 ms)
50 s min.
Approx. 1 A
Approx. 1.5 A
2
Approx. 0.7 A
s
electronic
Technical Data
UOP
1
1/1
5
1
1
A-3