Figure 3.8 Pipe Connections
Piping Support
Use brackets or hangers to support the gas piping. If you
have questions, consult your local gas company.
Control Motor
Install a control motor to modulate the air butterfly valve if
not factory installed on the burner.
NOTE: Be sure the control motor shaft and air butterfly
valve shaft are aligned properly.
Motor
BV
Shaft
Shaft
Set
Screws
Figure 3.9 Control Motor
10
Bracket
Pipe
Union
Control
Motor
Coupling

Checklist After Installation

To verify the system was properly installed, perform the
following checks:
1. Be sure there are no leaks in the gas lines.
2. Be sure all the components contained in the flame
monitoring and control systems are properly installed.
This includes verifying that:
• all the switches are installed in the correct locations.
• all wiring, pressure, and impulse lines are properly
connected.
3. Be sure all components of the spark ignition system
are installed and functioning properly.
4. Be sure the blower rotates in the proper direction. If the
rotation is incorrect, have a qualified electrician rewire
the blower to rotate in the proper direction.
5. Be sure all valves are installed in the proper location
and correctly oriented relative to the flow direction.
Eclipse Winnox Burner, WX Series, V2, Installation Guide 111, 2/26/2010