Function - Siemens 7XV5461-0B 00 Series Directions For Use Manual

Wide area fibre-optic repeater
Table of Contents

Advertisement

Available languages

Available languages

7XV5461-0Bx00

Function

Error
Port 1 Data
Port 2 Data
Power On
Reset/Echo Mode
Rx
Port 1
Tx
Rx
Port 2
Tx
Figure 4 Hardware structure of the FO-Repeater (only one interface is available at port 3 of
bidirectional FO-Repeaters)
The FO-Repeater multiplexes data received on port 1 and port 2 to port 3. The data is
transmitted completely bit-transparent, i.e. direct forwarding of the information without itself
adding or filtering out information. The data received on port 3 is de-multiplexed in the device
and output to port 1 or port 2. Figure 1 shows a typical design with two 7XV5653 binary signal
transducers.
A remote connection can be established using the FO-Repeater and a protection data
interface module (FO17, FO18 or FO19, see page 49) corresponding to the desired range
used in the SIPROTEC 4 protection device (7SD610, 7SD52, 7SD53, 7SA52, 7SA6).
However, in this configuration port 2 of the FO-Repeater may not be
Note:
The order options of the bidirectional FO-Repeaters cannot be connected
with the protection interface modules in the protection device.
C53000-B1174-C173-5
GND
Internal Logic
Grounding screw
_
U
H
+
3
2
GOK (DR)
1
Tx
Rx
used.
English
Port 3
47

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents