Comtech EF Data RADYNE RRS11 Installation And Operation Manual page 20

Solid-state transfer switch
Table of Contents

Advertisement

RRS11 Solid-State Transfer Switch
Table 3-1A, RRS11-L L-Band Rear Panel Connectors
Connector
Nomenclature
ID
J1
Online Status
Output
J2
Prime Mod Control
J3
Backup Mod Control
J4
Monitor A Input
J5
Monitor B Input
J6
On-Line Output
J7
Off-Line Output
J8
L-Band Input A
J9
L-Band Input B
Each modulator has a 9-Pin D-Sub Connector that connects to the RRS11 switch. A 1:1 cable is
connected from each modulator to the RRS11 switch. The pinout for the control connector is
listed in Table 3-2.
Pin No.
Signal Name
5
Signal Ground
9
Backup Select
1
+DC
2
nPrime_Sel
7
nBackup_Sel
8
Fault-In
4
Fault-Out
3
Switch-State
6
NC
MN-RRS11
Rev. 3
9-Pin D-Sub Switch Status Form-C Relay Outputs
9-Pin D-Sub Control Connector From Prime Modulator
9-Pin D-Sub Control Connector From Backup Modulator
SMA 50 Ohm from Modulator A Monitor Output
SMA 50 Ohm from Modulator B Monitor Output
N-Type 50 Ohm, Output of On-Line Modulator to Uplink Chain.
N-Type 50 Ohm Output of Monitor Port of Off-Line
Table 3-2. Switch Prime/Backup Control Pinout
Direction
Input
Output
Input
Input
Input
Input
Output
Output
---
Description
Modulator
SMA 50 Ohm From Modulator A
SMA 50 Ohm From Modulator B
Description
Modulator GND
One modulator is designated as Backup. This line
is tied low on the Backup Mod Control connector.
+12V DC Power
Forces On-Line Output to Prime
Forces On-Line Output to Backup
Fault Output From Modulator
Connects to Fault-In Monitor on Modulator
Switch State Monitor.
Logic '1' = Prime Online
---
Operation
3–4

Advertisement

Table of Contents
loading

Table of Contents