CAUTION:
The power control button on the device and the power switch on the power supply do not turn off the
electrical current that is supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
Install the M.2 backplane before installing the riser for adapter slots 16 through 17.
CAUTION:
Make sure that all server power cords are disconnected from their power sources before performing
this procedure.
Attention: Do not use the riser for slots 16 and 17 with four socket storage rich configurations.
Before you install the optional riser for slots 16 and 17:
1. If the I/O tray is installed in the server, remove it. See "Remove the I/O tray" on page 218.
2. Make sure that there is no screw (item 2 in following figure) securing the I/O tray board to the I/O tray in a
location where a captive riser screw will be installed.
3. Make sure that there are no I/O tray fillers installed in adapter slots 16 and 17.
4. Install adapters in the riser. See "Install an I/O adapter in slots 16 and 17" on page 186.
5. If any of the adapters in the riser have internal cables, make sure that they are connected before
installing the riser in the I/O tray.
Complete the following steps to install the riser for slots 16 and 17.
Watch the procedure. A video of the installation process is available:
YouTube
Youku
126
ThinkSystem SR950 Setup Guide