Download Print this page
Daikin VKM50GAMV1 Operation Manual

Daikin VKM50GAMV1 Operation Manual

Total heat exchanger, hrv heat reclaim ventilation with dx coil, ceiling mounted duct type, with dx coil/& humidifier
Hide thumbs Also See for VKM50GAMV1:

Advertisement

Total Heat Exchanger
HRV (Heat Reclaim Ventilation) -with DX Coil-
MODELS
(Ceiling mounted duct type)
With DX coil & Humidifier
VKM50GAMV1
VKM80GAMV1
VKM100GAMV1
With DX coil
VKM50GAV1
VKM80GAV1
VKM100GAV1
OPERATION MANUAL
English
Deutsch
Français
Español
Italiano
ΕλληνικÜ
Nederlands
Portugues
Рóссêий

Advertisement

loading
Need help?

Need help?

Do you have a question about the VKM50GAMV1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin VKM50GAMV1

  • Page 1 OPERATION MANUAL English Total Heat Exchanger HRV (Heat Reclaim Ventilation) -with DX Coil- Deutsch Français MODELS (Ceiling mounted duct type) With DX coil & Humidifier Español VKM50GAMV1 VKM80GAMV1 VKM100GAMV1 Italiano With DX coil VKM50GAV1 ΕλληνικÜ VKM80GAV1 VKM100GAV1 Nederlands Portugues Рóссêий...
  • Page 2 HRV; Wärmerückgewinnungslüftung ìονÜδαò VRVII για Ýλεγχο τηò ìονÜδαò. • Danke, dass Sie sich für den Wärmetauscher von Daikin entschieden haben. Lesen Sie diese Bedienungsanleitung sorgfältig, ehe Sie den Wärmetauscher in HRV; Hergebruik van warmte Betrieb nehmen. Hier erfahren Sie, wie Sie das Gerät korrekt betreiben. In diesem •...
  • Page 3 MODELS VKM50GAMV1 VKM80GAMV1 VKM100GAMV1 VKM50GAV1 VKM80GAV1 VKM100GAV1 (1) Hanger bracket (7) Maintenance cover (8) Heat exchanger elements (3) Exhaust fan It exchanges the heat (temperature and humidity) from indoors with the air taken in from outdoors, (2) Duct connecting flange changes the outside air to the same condition as indoors and then brings it indoors.
  • Page 4 • Combined operation system with VRV systems Indoor unit HRV-With DX Coil- Remote controller for indoor unit Outdoor unit • Independent system HRV-With DX Coil- Outdoor unit Remote controller Remote controller for VRV BRC1A62 for indoor unit Remote controller for VKM BRC1D527 (EU only) UNIT No.
  • Page 5 UNIT No. GROUP 1,2,3 1,2,3 Remote controller for VKM BRC1D527 (EU only) Remote controller for VRV BRC1A62 UNIT No. GROUP 1,2,4 Remote controller for VKM BRC1D527 (EU only) Remote controller for VRV BRC1A62 (1) Air filter (1) Heat exchanger element (×2) (2) Handle (3) Rail...
  • Page 6: Table Of Contents

    With DX coil & Humidifier With DX coil Total Heat Exchanger Operation VKM50GAMV1 VKM50GAV1 VKM80GAMV1 VKM80GAV1 HRV (Heat Reclaim Ventilation) -with DX Coil- manual VKM100GAMV1 VKM100GAV1 • Do not wash the HRV unit with water. CONTENTS Electric shock or fire may result. (Not including air filters, etc.)
  • Page 7 • Do not place objects in direct proximity of the outdoor • For refrigerant leakage, consult your dealer. unit and do not let leaves and other debris accumulate When the HRV unit is to be installed in a small room, it is around the unit.
  • Page 8: What To Do Before Operation

    This operation manual is for the following systems with stan- • Ask your dealer to move and reinstall the unit. dard control. Before initiating operation, contact your Daikin Incomplete installation may result in a water leakage, elec- dealer for the operation that corresponds to your system type tric shock, and fire.
  • Page 9 ∗2 Operation lamp (red) 18 Temperature setting button The lamp lights up during operation or blinks if a malfunc- Use this button for setting the desired temperature of air tion occurs. conditioner combined with this unit. This button can’t use for this unit. ∗3 Display “...
  • Page 10 34 MINIMUM SET TEMPERATURE “ ” During intermediate periods when only the HRV unit is used The minimum set temperature indicates the minimum set without the air conditioner, select “ventilation” with the opera- temperature when in limit operation. tion selection button.(Refer to 2.4) ∗35 SCHEDULE TIMER ICON “...
  • Page 11 Example 1: Example 2: In case of the remote controller “BRC1D527” and as equiva- In case of the remote controller “BRC1A62” lent. Display changes as below. Display changes as below. When air conditioner and HRV unit are not connected via duct When air conditioner and HRV unit are not connected via duct <Operation mode>...
  • Page 12: Operation Procedure

    2.5 NIGHTTIME FREE COOLING OPERATION NOTE 〈AUTOMATIC HEAT PORGE FUNCTION AT NIGHT〉 • “ ” can only be set for systems operating in cooling and The nighttime free cooling is an energy-conserving function heating at the same time. which works at night when the air conditioners is off, reducing “...
  • Page 13 (Not producted a single outdoor unit. by Daikin) and based on only the infor- mation from the HRV unit (indoor and outdoor temperatures) when the HRV unit is operating alone.
  • Page 14 3.3 PROGRAMMING START AND STOP OF THE (Simultaneous cooling/heating systems) SYSTEM WITH TIMER If multiple indoor units or many 3.3.1 HOW TO PROGRAM AND SET THE TIMER WITH THE of this unit are connected to REMOTE CONTROLLER “BRC1A62” (Refer to figure 7) outdoor unit via BS unit.
  • Page 15 When you want to start operation after a desired time has Press the “ ” button. “ ” icon displays. elapsed This icon means the unit will stop at the set time. Example: When all data for the schedule timer actions for Monday Set the time to “8”.
  • Page 16: Maintenance (For A Qualified Service Person Only)

    • Use city water or clean water and take steps to prevent • If the dirt becomes impossible to clean, change the air filter condensation from forming. (VKM-GAMV1 series only) (Air filter for exchange is optional). (1) Detach the maintenance cover. •...
  • Page 17: Trouble Shooting

    (4) Use a vacuum cleaner to remove dust and foreign objects For dealers on the surface of the heat exchange element. Content of maintenance Problems if (Refer to figure 12) Inspected maintenance Items to be • Use the vacuum cleaner equipped with a brush on the part is not carried Solution...
  • Page 18 Operation automatically restarts when the noise goes away. Measure: Notify and inform the model name and what the • “88” is displayed on the remote controller. malfunction code indicates to your Daikin dealer. <Symptom> • There are other malfunctions. It displays immediately after the power is turned on, and dis- Measure: Stop the unit.
  • Page 19 After-sales service and warranty In case of the malfunction with the code in white letters on the black background in the unit still operates. After-sales service: However, be sure to have it inspected and repaired and as soon as possible. WARNING If other than the above error codes are displayed, there is a possibility that the problem in question has...
  • Page 20 • Table 1 “Inspection Cycle” and “Maintenance Cycle” Lists Recommended replacement cycle of wear-out parts [The cycle is not the same as the warranty period.] Maintenance Cycle Inspection Name of Main Part [replacements and/ • Table 2 “Replacement Cycle” Lists Cycle or repairs] Inspection...
  • Page 21 3P130767-3G EM05A069A (0704) HT...

This manual is also suitable for:

Vkm80gav1Vkm80gamv1Vkm100gav1Vkm100gamv1Vkm50gav1