Download Print this page
Daikin VAM350FC Operation Manual
Hide thumbs Also See for VAM350FC:

Advertisement

OPERATION MANUAL
Total Heat Exchanger
HRV (Heat Reclaim Ventilation)
(Ceiling mounted duct type)
VAM350FC
VAM500FC
VAM650FC
VAM800FC
VAM1000FC
VAM1500FC
VAM2000FC

Advertisement

loading

Summary of Contents for Daikin VAM350FC

  • Page 1 OPERATION MANUAL Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM350FC VAM500FC VAM650FC VAM800FC VAM1000FC VAM1500FC VAM2000FC...
  • Page 4: Table Of Contents

    HRV – Heat Reclaim Ventilation or for commercial use by lay persons. Before using the DAIKIN HRV, be sure to read this This appliance is not intended for use by persons ...
  • Page 5: Names Of Parts

    Names of parts Operation method The remote controller for air conditioner turns the air conditioner and Refer to figure 1 (models VAM350~1000F) and figure 2 (models HRV unit on and off. VAM1500~2000F) If only the HRV unit is used without operating the air conditioner, set Ceiling hook the unit in the “...
  • Page 6 Operation with the remote control exclusively for Air Ventilation mode changeover button conditioning operation HRV units (BRC301B61) “ ” Automatic mode. The temperature sensor of the unit automatically For non-independent systems, starting/stopping operation and timer changes the ventilation of the unit in Bypass mode and operation may not be possible.
  • Page 7: Maintenance

    Operating the HRV unit using the remote controller of the Every time the operation mode selector is pressed, the  operation mode display changes as shown below. VRV-system air conditioner Example Please read the manual supplied with the remote controller for more detailed instructions (optional controllers: BRC1D52 or BRC1E52).
  • Page 8: Trouble And Countermeasure

    Take out the heat exchange elements from the unit body. Maintenance for the heat exchange element (Refer to figure 4 (A = Models VAM350~1000F, B = Models VAM1500~2000F)) Cleaning frequency At least once every two years (for general office use) Heat exchange element (clean the element more frequently if necessary.) Handle...
  • Page 9: Disposal Requirements

    Disposal requirements Dismantling of the unit must be done in accordance with relevant local and national legislation. Operation manual VAM350~2000FC Total Heat Exchanger HRV (Heat Reclaim Ventilation) 4P415945-1 – 2015.08...