Wen 56225i Instruction Manual page 21

2250w inverter generator
Hide thumbs Also See for 56225i:
Table of Contents

Advertisement

SOME NOTES ABOUT POWER CORDS
Long or thin cords can drain the power provided to an electrical device by the generator. When using such cords,
allow for a slightly higher rated wattage requirement by the electrical device.
Device Requirements
Amps
Watts
(120V)
2.5
300
5
600
7.5
900
10
1200
15
1800
20
2400
25
3000
30
3600
40
4800
*NR = Not Recommended
WARNING! Generator should only be connected to electrical devices, either directly or with an extension
cord. NEVER CONNECT TO A BUILDING ELECTRICAL SYSTEM without a qualified electrician and connected to
a transfer switch as a separately derived system. Such connections must comply with local electrical laws and
codes. Failure to comply can create a back-feed, which may result in serious injury or death to utility workers.
NOTE: For power outages, permanently installed, stationary generators are better suited for providing backup
power to your home. Even a properly connected portable generator can become overloaded. This may result in
overheating or stressing the machine's components, possibly leading to generator failure.
USING YOUR GENERATOR
Watts (240V)
#8 wire
600
NR
1200
NR
1800
NR
2400
NR
3600
NR
4800
175
6000
150
7200
125
9600
Max. Cord Length (ft) by Wire Gauge
#10 wire
NR
NR
350
250
150
125
100
65
90
NR
Table 3 - Power Cord Requirement Guide
#12 wire
#14 wire
NR
375
300
200
200
125
150
100
100
65
75
50
60
NR
NR
NR
NR
NR
#16 wire
250
125
100
50
NR
NR
NR
NR
NR
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

56200i

Table of Contents