CONNECTING ELECTRICAL DEVICES
When the rated wattage requirement of each electrical device has been determined, add these numbers to find the
total rated wattage needed. If this number exceeds the rated wattage (1800W) of the generator, DO NOT connect all
these devices. Select a combination of electrical devices with a total rated wattage lower than or equal to the rated
wattage of the generator.
CAUTION! Become familiar with the markings on the control panel (Fig. 11) before connecting electrical
devices. Do not connect 50Hz loads to the generator.
1. Before connecting electrical devices, allow the generator to run for a few minutes to stabilize the speed and volt-
age output.
2. Make sure that all devices are turned off. Start plugging in each electric device, from the highest wattage to the
lowest. Check the power indicator light (green) to ensure the generator is producing power.
3. Do not overload the generator or individual panel receptacles. If an overload occurs, the overload indication light
(red) will activate. If it is flashing, turn off and unplug one load. If it is solid (not flashing), the generator will cut
off power to protect itself. Unplug all electrical devices and then press the reset button to reset the entire circuit,
or press the circuit breaker to reset the DC circuit. Check the total wattage of the devices and reduce the load if it
exceeds the capacity of the generator. Then, plug the loads back in one by one.
NOTE: If the reset button or circuit breaker does not reset, wait several minutes and try again. If problem still per-
sists, please call 1-(800) 232-1195 M-F 8-5 CST.
Low Oil Indicator
3-in-1 Dial Switch
Reset Button
Manual Shut-Off
Eco-Mode Switch
NOTE: The NEMA 5-20 receptacles are capable of connecting devices up to 20A only when two generators are
parallel connected. When operating a single generator, do not exceed 15A (1800 running watts) on this receptacle.
USING YOUR GENERATOR
OFF
RUN
CHOKE
MANUAL
SHUT OFF
ECO-MODE
PARALLEL CONNECT
ON
OFF
AC 120V
RESET
DC 5V
GROUNDING
Fig. 11
Output Indicator
Overload Indicator
AC 120V Duplex
NEMA 5-20R
DC 5V USB Outlet
Grounding Nut
Parallel Connection
19