Memory Unit - ABB MicroFlex e190 Quick Installation Manual

Hide thumbs Also See for MicroFlex e190:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
E1 / E2: Ethernet port configuration
The rotary switches are read once at start-up.
The switches select the mode of operation for
the E1 and E2 Ethernet fieldbus connectors on
the top panel of the drive.
Value
00
01-EF
F0
F1
F2-FF
X7: Incremental encoder in / out
The secondary incremental encoder input/
output connection provides A/B channels and a
Z index channel.
Pin 1
1
CHA+
2
CHB+
3
CHZ+
4
(NC)
5
GND
SW2: feedback supply voltage
SW2 sets the supply output voltage on
feedback connector X8, pin 12. Check that the
correct output voltage is selected. Most
feedback devices require 5 V, but some
Hiperface devices require 8 V.
Mode
EtherCAT slave mode
Ethernet POWERLINK CN mode:
selected value is the node ID
Reserved
Reserved
Reserved
6
CHA-
7
CHB-
8
CHZ-
9
(NC)
SW2
5 V
8 V

Memory unit

The memory unit is an essential part of the
drive and must always be fitted. It is not
designed for frequent removal and insertion.
• Open the memory unit:
• Insert the memory unit:
User's manual
Continue with drive start-up according to the
instructions in MicroFlex e190 User's Manual.
Quick installation guide - MicroFlex e190
9
1
2

Advertisement

Table of Contents
loading

Table of Contents