WARNINGS FOR ORDINARY USE
OF THE MECHANISM
7.1 - Maximum continuous work cycle
In general, the motors in the "Era" line were designed for residential use and there-
fore for discontinuous use. They guarantee a maximum operating time of 4 minutes
and in cases of overheating (e.g. caused by continuous prolonged operation) a "ther-
mal protector" for safety intervenes to cut out the power supply, restoring it when the
temperature returns to normal.
7.2 - "Automatic limit switch update"
function
The limit switches adjusted through the impact of the box against the structure or
other mechanical blocks are verified by the "Automatic limit switch update" function
every time the awning performs a maneuver and bumps into its limit switches. This
allows the function to measure the new limit switch values and update the existing
ones, thereby recovering any slack that may have occurred throughout time due to
wear and/or thermal shocks to which the parts of the structure are subjected. The
constant update of the heights allows the awning to always reach the limit switch
with maximum precision.
This function is not activated when the stroke of the awning lasts for less than 2.5
seconds and does not reach the limit switch.
7.3 - Commanding partial opening/closing of the
awning (height "H")
In general, to command the partial opening/closing of the awning, press the key as-
sociated with the partial height during programming (for more information, read point
06 of procedure 5.7). If the transmitter has only three keys and only one "H" height is
memorised, simultaneously press keys s and t to recall this height.
What to do if...
(troubleshooting guide)
l Powering an electrical phase, the motor does not move:
After excluding the possibility that thermal protection is active, in which case it is
sufficient to wait for the motor to cool down, make sure the mains voltage corre-
sponds to the values indicated in the technical characteristics of this manual by
measuring the electricity between the "common" wire and the electrical phase
wire supplied with current. Finally, try to supply the opposite electrical phase.
l When sending a Raise command, the motor does not start:
This can happen if the awning is near the Upper limit switch ("0"). In this case
you must lower the awning a little bit and give the Raise command again.
l The system operates in the emergency condition with an
operator present:
– Check to see if the motor has undergone a significant thermal
or mechanical shock.
– Make sure each part of the motor is still in good condition.
– Perform the deletion procedure (paragraph 5.10) and adjust
the limit switches again.
Disposal of the product
As in installation operations, disposal operations must be performed by qualified per-
sonnel at the end of the product's lifespan.
The product is made of various types of materials: some of them may be recycled,
while others must be scrapped. Find out about recycling and disposal systems in
use in your area for this product category. Warning! – Some parts of the product
may contain polluting or hazardous substances which, if released to the environ-
ment, may cause serious damage to the environment or to human health. As indicat-
ed by the symbol appearing here, the product may not be disposed of
with other household wastes. Separate the waste into categories for
disposal, according to the methods established by current legislation
in your area, or return the product to the retailer when purchasing a
new version. Warning! – Local legislation may impose heavy fines in
the event of illegal disposal of this product.
The product's packaging materials must be disposed of in full compliance with lo-
cal regulations.
Technical specifications
l Power supply voltage: see data on rating plate
l Power drawn in Stand-by mode: 0.5 W
l Resolution of the encoder: 2,7°
l Continuous operation time: 4 minutes
l Minimum operating temperature: -20°C
l Level of protection: IP 44
Notes • All technical specifications stated in this section refer to an ambient tem-
perature of 20°C (± 5°C). • Nice reserves the right to apply modifications to prod-
ucts at any time when deemed necessary, maintaining the same intended use and
functionality.
CE declaration of conformity
Declaration number: 454/Era Mat Zero VS
Nice S.p.A. hereby declares that the products: E Mat SVS(...), E Mat MVS(...), E Z
MVS(...) conform to the essential requisites and other pertinent provisions laid down
by directives 1999/5/EC, 2006/95/EC, 2004/108/EC. The EC declaration of con-
formity can be consulted and printed at www.nice-service.com or requested from
Nice S.p.A.
Mr. Mauro Sordini
(Chief Executive Officer)
English – 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Era zero vs

Table of Contents