Maintenance

9.
Maintenance
 You should only use spare parts which have been manufactured or approved by DewertOkin.
Only these parts will guarantee a sufficient level of safety.
9.1
Maintenance
Type of check
Check the function and safety
of the electrical system.
Look over the housing periodi-
cally for any signs of damage.
Look over the plug-in connec-
tions and electrical access
points for signs of damage.
Look over the cables for any
signs of damage.
9.2

Cleaning and care

The AG300 is easy to clean. Its smooth surfaces simplify the cleaning process.
NOTICE
Never clean the AG300 in an automated washing system or with a high-pressure
cleaner. Do not allow fluids to penetrate the unit. Damage to the system could result.
Do not use a cleanser that contains benzene, alcohol or similar solvents.
1 Be sure to unplug the drive cable on the AG300 before you begin cleaning it!
2 Clean the AG300 with a moist cloth.
3 Be sure that you do not damage the connecting cables during the cleaning.
28
Explanation
A qualified electrician should carry
out this inspection. (Refer to the
"Electrical connection" section in
the "Installation" Chapter.)
Check the housing for breaks or
cracks.
Check that all electrical cables
and connections are firmly seated
and correctly positioned.
Check the connecting cables for
pinching or shearing. Also, check
the strain relief and kink protec-
tion mechanisms, in particular af-
ter any mechanical load.
AG300
Time interval
Periodic inspections can
be carried out at intervals
based on the risk as-
sessment which you con-
duct for your end product.
At least every six months.
At least every six months.
At least every six months.
81423(-)