Phoenix Mecano DewertOkin AG300 Installation Instructions Manual page 21

Table of Contents

Advertisement

AG300
6.2.4
Electrical connection
Routing the electrical cables
When routing the cables, be sure that:
• the cables cannot get jammed,
• no mechanical load (such as pulling, pushing or bending) will be put on the cables, and
• the cables cannot be damaged in any way.
Fasten all cables (especially the connecting cables) to the end product using sufficient kink preven-
tion methods. Be sure that the design of the end product prevents the connecting cables from com-
ing into contact with the floor during transport.
6.2.5
Removing the AG300
You should only connect and disconnect the cables when they are completely discon-
nected from any live current!
1 First, remove all strain relief and caps from the AG300 connection. Then disconnect the battery
plug from the socket on the drive or control unit.
2 Take the battery out of the drive's holder or from the end product. You will need to press the
battery's locking clip in until the battery can be pulled out of the compartment.
3 Insert the dummy plug (if available) for the battery socket on the drive or control unit.
4 Put the cap over the connection on the drive or control unit. Then secure the cap in place.
81423(-)
CAUTION
Installation
21

Advertisement

Table of Contents