Advertisement

Quick Links

AG300
Installation Instructions
(Translation of the original installation instructions)

Advertisement

Table of Contents
loading

Summary of Contents for Phoenix Mecano DewertOkin AG300

  • Page 1 AG300 Installation Instructions (Translation of the original installation instructions)
  • Page 3: Foreword

    AG300 Foreword Foreword Document revision history Version Date Modification, change 06/2015 First release Disclaimer and exclusion of liability DewertOkin is not responsible for damage resulting from: • failure to observe these instructions, • changes made to this product which have not been approved by DewertOkin, or •...
  • Page 4: Notice For Customers In Eu Nations

    Foreword AG300 Notice for customers in EU nations German Inspection Authority (TÜV SÜD Product Service) testing label The construction of the AG300 has been inspected by the German TÜV SÜD Product Service In- spection Authority. TÜV SÜD Product Service also monitors the production of the AG300. The offi- cial German TÜV SÜD Product Service certifies this construction inspection and production moni- toring.
  • Page 5: Table Of Contents

    AG300 Table of contents Table of contents Foreword Document revision history Disclaimer and exclusion of liability Manufacturer's address Creation of a complete operating instruction manual for the entire end product Usage in medical products Notice for customers in EU nations Table of contents General Information About these installation instructions...
  • Page 6 General Information AG300 Troubleshooting Maintenance Maintenance Cleaning and care Note on maintenance and care Disposal 10.1 Packaging material 10.2 Components of the AG300 10.3 Batteries EU Declaration of Conformity 81423(-)
  • Page 7: General Information

    AG300 General Information General Information About these installation instructions These installation instructions must be followed closely in order to install the AG300 successfully and safely. These instructions are not an operating manual for the end product. These instructions will help you to minimize danger, repair costs and down times. They will also help you to maximize the reliability and lifespan of the end product.
  • Page 8: Safety Notices

    Safety notices AG300 Safety notices Proper and intended usage The AG300 is intended to be used as an independent power supply for suitable DewertOkin drive systems: • for care purposes, • or in hospitals. CAUTION The AG300 should only be used for the applications described above. Any other use is forbidden.
  • Page 9: Selection And Qualification Of Personnel

    AG300 Safety notices Battery-operated reset function The AG300 has a battery-operated reset function. CAUTION The battery-operated reset function is not a safety system and does not avert danger. DewertOkin does not guarantee that the drive will function in the event of a power outage. If the end-product manufacturer chooses to guarantee the functionality of the end product during a power outage, then the end-product manufacturer is responsible for arranging a mechanism to en- sure this functionality.
  • Page 10: Notice On Safety During Operations

    Safety notices AG300 Notice on safety during operations Basic safety rules must be followed in order to ensure that the end product can be continually op- erated in a safe manner. These rules must be observed while using the end product and while in- stalling the AG300 in the end product.
  • Page 11: Product Labelling

    AG300 Safety notices Product labelling 2.4.1 Ratings plate (type label) A ratings plate on each AG300 specifies the exact name and serial number. It also states the tech- nical specifications valid for that particular AG300. The following illustrations show where the speci- fications are located on the ratings plate of the AG300.
  • Page 12: Possible Combinations

    Possible combinations AG300 Possible combinations The AG300 can be combined with various components. The following basic combinations are pos- sible: • An AG300 connected to a DUOMED, • An AG300 connected to a SGAG300. Systems can be customized by combining the drive, control unit, AG300 and handset. DewertOkin has separate system instruction manuals containing the additional information and in- structions needed for these systems.
  • Page 13: Description

    AG300 Description Description The AG300 lead battery is used as an emergency power supply for one or more DewertOkin drives. The AG300 can be charged in the following ways: • using a charging circuit in the drive or in the control unit, •...
  • Page 14: Technical Specifications

    Technical specifications AG300 Technical specifications AG300 Rated voltage 24 V DC Capacity 1.1 – 1.3 Ah Fuse T 15 A Protection degree IPX4, IP44, IPX6, IP66 Battery type Lead fleece Final charging voltage 26.5 V – 29.0 V DC (depending on the control unit) Charging time Approx.
  • Page 15 AG300 Technical specifications Figure 4 Dimensions of the AG300, top view (in mm) Figure 5 Dimensions of the AG300, side view (in mm) 81423(-)
  • Page 16: Installation

    Installation AG300 Installation Safety notices to observe during installation Basic safety rules must be followed in order to ensure that the end product can be continually op- erated in a safe manner. These rules must be observed while using the end product and while in- stalling the AG300 in the end product.
  • Page 17: Installation Procedure

    AG300 Installation Installation procedure Before installing and connecting the AG300, make sure that you are observing all of the safety no- tices found in the "Safety notices to observe during installation" section. • The AG300 can be inserted into the holder on the DUOMED or SGAG300. •...
  • Page 18 Installation AG300 6.2.2 Connecting the AG300 to the SGAG300 control unit CAUTION Work on electrical components should be conducted only when the mains power con- nection is unplugged. Figure 7 Connecting the AG300 to the SGAG300 control unit A SGAG300 B AG300 C Plug for the AG300 connecting cable D Battery socket...
  • Page 19 AG300 Installation 6.2.3 Mounting the AG300 to the end product Six screws should be used at the six mounting points to attach the AG300 mounting plate to the end product. The mounting plate should be mounted so that it lies flat against its supporting base. In the end product, no mechanical forces (such as torsion) should be put on the mounting plate or the AG300.
  • Page 20 Installation AG300 Figure 9 Attaching the mounting plate and inserting the AG300 A Mounting plate B AG300 Proceed as follows to install and attach the mounting plate to the AG300: 1 Mark the positions of the mounting points on your end product. 2 Drill out the mounting points.
  • Page 21 AG300 Installation 6.2.4 Electrical connection Routing the electrical cables When routing the cables, be sure that: • the cables cannot get jammed, • no mechanical load (such as pulling, pushing or bending) will be put on the cables, and • the cables cannot be damaged in any way. Fasten all cables (especially the connecting cables) to the end product using sufficient kink preven- tion methods.
  • Page 22: Operating Notes

    Operating notes AG300 Operating notes The factual information contained within may be used when you are creating the end-product man- ual. The installation instructions do not contain all information required for the safe operation of the end product. They only describe the assembly and operation of the AG300 as a partially assem- bled piece of machinery.
  • Page 23 AG300 Operating notes Deep-discharge protection The drive system is completely deactivated whenever the voltage of the AG300 has reached the shutdown threshold level. This deep discharge monitor protects the rechargeable battery from damages that could result when the discharge warning is ignored. ...
  • Page 24: Information About Commissioning The Ag300

    Operating notes AG300 Information about commissioning the AG300 • Connect the AG300 with the drive or control unit as described in section 7.2. • Charge the AG300 completely (for at least 24 hours) before first use. The installed batteries achieve their full capacity only after 5 to 10 charge/discharge cycles. Safety instructions for operating and charging the AG300 •...
  • Page 25: Charging The Ag300

    AG300 Operating notes Charging the AG300 The AG300 is charged by the drive or control unit that it is connected to. It is also possible to use an external charging station to charge the AG300 (as shown in Figure 10). NOTICE The AG300 should only be charged by drives or control units from DewertOkin since they have already been verified to work together.
  • Page 26: Charging Display On The Handset (Examples)

    Operating notes AG300 Charging display on the handset (examples) Custom handsets can be delivered for use with the AG300. The charging status is indicated by the Power On LED. Two examples are shown below. ® Figure 12 The IPROXX SE and IPROXX 2 handsets (examples) ®...
  • Page 27: Troubleshooting

    AG300 Troubleshooting Troubleshooting This chapter describes troubleshooting methods for fixing problems. If you experience an error that is not listed in this table, please contact your supplier. CAUTION Only qualified specialists who have received electrician training should carry out trou- bleshooting and repairs.
  • Page 28: Maintenance

    Maintenance AG300 Maintenance  You should only use spare parts which have been manufactured or approved by DewertOkin. Only these parts will guarantee a sufficient level of safety. Maintenance Type of check Explanation Time interval Check the function and safety A qualified electrician should carry Periodic inspections can of the electrical system.
  • Page 29: Note On Maintenance And Care

    AG300 Maintenance Note on maintenance and care 9.3.1 Maintenance information • Plastic surfaces (such as the housing surface) should only be cleaned with a damp cloth. • Charge the AG300 before you use it. Always use a control unit or drive from DewertOkin that has an integrated charging circuit for charging the battery.
  • Page 30: 10. Disposal

    Disposal AG300 10. Disposal 10.1 Packaging material The packaging material should be sorted into recyclable components and then disposed of in ac- cordance with the appropriate national environmental regulations (in Germany according to the re- cycling law KrWG from 01.06.2012; internationally according to the EU Directive 2008/98/EC (Waste Framework Directive WFD as of 12.12.2008)).
  • Page 31: Eu Declaration Of Conformity

    EU Declaration of Conformity EG-Konformitätserklärung In compliance with Appendix IV of the EMC-Directive Nach Anhang IV der EMV-Richtlinie 2014/30/EU 2014/30/EU In compliance with Appendix IV of the LVD-Directive Nach Anhang IV der EU-Niederspannungsrichtlinie 2014/35/EU 2014/35/EU Nach Anhang VI der RoHS-Richtlinie 2011/65/EU In compliance with Appendix VI of the EU RoHS (inkl.
  • Page 32 DewertOkin GmbH Weststrasse 1 Kirchlengern 32278, Germany Tel: +49(0)5223/979-0 Fax.: +49 0 522375182 http://www.dewertokin.de Info@dewertokin.de ID No.: 81423...

Table of Contents