6.2.3
Mounting the AG300 to the end product
Six screws should be used at the six mounting points to attach the AG300 mounting plate to the
end product. The mounting plate should be mounted so that it lies flat against its supporting base.
In the end product, no mechanical forces (such as torsion) should be put on the mounting plate or
the AG300. Such forces could lead to damage (such as cracks) in the housing.
Work on electrical components should be conducted only when the mains power con-
nection is unplugged.
NOTICE
The following information is important when mounting the AG300:
• Charge the AG300 completely (for at least 24 hours) before first use. The installed
• The air vents on the AG300 must not be covered during the charging process.
• When mounting the AG300, make sure that it is not lying on its top (upside down)
• Allow the AG300 to rest for about 1 hour after charging it; this will prolong its life-
Ø 4.5
Figure 8
81423(-)
CAUTION
batteries achieve their full capacity only after 5 to 10 discharge cycles.
and the connecting cable is not facing downwards. The AG300 may only be
charged when it is properly positioned (as shown in Figure 11).
span.
74
Mounting points on the AG300 mounting plate (specifications in mm)
80
142
334
358
Installation
74
108
19